Validation of an algorithm that separates gaseous micro-embolic signals and artifacts during transcranial Doppler persistent foramen ovale examinations

Persistent foramen ovale (PFO) is a risk factor for young stroke. Agitated saline serum is used to deliver small gaseous emboli to the brain in transcranial Doppler ultrasound (TCD) for the detection and grading of PFO. In this study we validated a PFO algorithm that can differentiate between gaseous emboli and artifacts. The validation cohort comprised 18 patients with positive PFO examinations. The PFO algorithm uses a binary tree that separates high-intensity transients signals (HITs) into gaseous emboli or artifacts based on intensity, zero-crossing, and velocity parameters. The cohort exhibited 385 macroscopic gaseous emboli meeting the >3 dB criterion. An additional 137 gaseous emboli were noticed below the 3-dB intensity cutoff value. The low-intensity gaseous emboli included both macroscopic and microscopic air bubbles observed in curtains. Nearly all emboli (98 %) above the 3-dB level showed overt frequency modulation. The overall accuracy of the PFO algorithm in discriminating macroscopic gaseous emboli and artifacts was 96.4 %, with a similar percentage of sensitivity and specificity (96.4 %). The inter-observer agreement of human experts was excellent (ic-CC 0.989 and 0.953). Macroscopic gaseous emboli and artifacts during PFO exams can be accurately discriminated by the PFO algorithm. The PFO algorithm cannot be used as a standalone system as microscopic air bubbles might escape proper identification. This knowledge will be important in the design of future PFO algorithms which should make it possible to classify the PFO grade without the interference of humans.

Authors

Publication Details

Journal
WFUMB Ultrasound Open
Published
2024-10-02
DOI
https://doi.org/10.1016/j.wfumbo.2024.100067
Citations
2
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of an algorithm that separates gaseous micro-embolic signals and artifacts during transcranial Doppler persistent foramen ovale examinations

R.W.M. Keunen, Sayonara Daal, Paulien M. van Kampen, Geert Jan Romers et al.
2 citations
WFUMB Ultrasound Open
Cardiovascular and Diving-Related Complications
0.84
article

Validation of an algorithm that separates gaseous micro-embolic signals and artifacts during transcranial Doppler persistent foramen ovale examinations

R.W.M. Keunen, Sayonara Daal, Paulien M. van Kampen, Geert Jan Romers, Hester Temmink, Mirjam Schipper
article en
2 citations

Abstract

Persistent foramen ovale (PFO) is a risk factor for young stroke. Agitated saline serum is used to deliver small gaseous emboli to the brain in transcranial Doppler ultrasound (TCD) for the detection and grading of PFO. In this study we validated a PFO algorithm that can differentiate between gaseous emboli and artifacts. The validation cohort comprised 18 patients with positive PFO examinations. The PFO algorithm uses a binary tree that separates high-intensity transients signals (HITs) into gaseous emboli or artifacts based on intensity, zero-crossing, and velocity parameters. The cohort exhibited 385 macroscopic gaseous emboli meeting the >3 dB criterion. An additional 137 gaseous emboli were noticed below the 3-dB intensity cutoff value. The low-intensity gaseous emboli included both macroscopic and microscopic air bubbles observed in curtains. Nearly all emboli (98 %) above the 3-dB level showed overt frequency modulation. The overall accuracy of the PFO algorithm in discriminating macroscopic gaseous emboli and artifacts was 96.4 %, with a similar percentage of sensitivity and specificity (96.4 %). The inter-observer agreement of human experts was excellent (ic-CC 0.989 and 0.953). Macroscopic gaseous emboli and artifacts during PFO exams can be accurately discriminated by the PFO algorithm. The PFO algorithm cannot be used as a standalone system as microscopic air bubbles might escape proper identification. This knowledge will be important in the design of future PFO algorithms which should make it possible to classify the PFO grade without the interference of humans.

WFUMB Ultrasound OpenVol. 2(2)
Openalex Percentile: Top 24%
Cardiovascular and Diving-Related Complications
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.