Clinical Implication of the New AI-TIRADS Classification of Thyroid Nodules; Our Real Clinical Experience

Background: Ultrasound and fine needle aspiration biopsy (FNAB) play a primary role in determining the nature of nodules. Objectives: The aim of our study is to determine the diagnostic accuracy, sensitivity, and specificity of artificial intelligence-thyroid imaging reporting and data system (AI-TIRADS) in differentiating malignant from benign nodules to establish the treatment plan for patients and avoid unnecessary FNAB. Methods: This cross-sectional study was conducted between September 2020 and September 2021 (one year). Patients (n = 133) who had an indication for surgery due to nodular thyroid disease and were referred to the therapeutic training center of 5 Azar and Falsafi private section hospitals, Gorgan, Iran, were included. The diagnostic accuracy of FNAB and AI-TIRADS was calculated. Results: The mean age of patients with malignant pathology (39.65 ± 11.69) was lower than that of patients with benign pathology (44.14 ± 13.54), which was statistically significant (P = 0.042). Fifty-two out of 72 nodules less than 25 mm were malignant, demonstrating a higher prevalence of benign pathology in larger nodules. A pooled analysis of thyroid reporting (TR) = 2 and TR points ≥ 7 for their power in predicting the final pathology outcome showed figures of 0.97, 0.93, 0.97, and 0.97 for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), respectively, with an overall pooled accuracy of 0.97 for these two groups of sonographic results. Conclusions: We concluded that AI-TIRADS has a high sensitivity and diagnostic accuracy in differentiating benign from suspicious nodules.

Authors

Publication Details

Journal
Shiraz E-Medical Journal
Published
2024-10-02
DOI
https://doi.org/10.5812/semj-147642
Citations
1
Primary Topic
Thyroid Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Implication of the New AI-TIRADS Classification of Thyroid Nodules; Our Real Clinical Experience

Sepideh Sadat Hosseini, Sina Mohajernoei, Mahin Tatari, Gholamreza Roshandel et al.
1 citations
Shiraz E-Medical Journal
Thyroid Cancer Diagnosis and Treatment
0.36
article

Clinical Implication of the New AI-TIRADS Classification of Thyroid Nodules; Our Real Clinical Experience

Sepideh Sadat Hosseini, Sina Mohajernoei, Mahin Tatari, Gholamreza Roshandel, Siamak Rajaei, Reza Afghani, S. Rezazadeh, A. Alijani, Mohammad Hadi Gharib, Zolaykha Karamollahi
article en
1 citations

Abstract

Background: Ultrasound and fine needle aspiration biopsy (FNAB) play a primary role in determining the nature of nodules. Objectives: The aim of our study is to determine the diagnostic accuracy, sensitivity, and specificity of artificial intelligence-thyroid imaging reporting and data system (AI-TIRADS) in differentiating malignant from benign nodules to establish the treatment plan for patients and avoid unnecessary FNAB. Methods: This cross-sectional study was conducted between September 2020 and September 2021 (one year). Patients (n = 133) who had an indication for surgery due to nodular thyroid disease and were referred to the therapeutic training center of 5 Azar and Falsafi private section hospitals, Gorgan, Iran, were included. The diagnostic accuracy of FNAB and AI-TIRADS was calculated. Results: The mean age of patients with malignant pathology (39.65 ± 11.69) was lower than that of patients with benign pathology (44.14 ± 13.54), which was statistically significant (P = 0.042). Fifty-two out of 72 nodules less than 25 mm were malignant, demonstrating a higher prevalence of benign pathology in larger nodules. A pooled analysis of thyroid reporting (TR) = 2 and TR points ≥ 7 for their power in predicting the final pathology outcome showed figures of 0.97, 0.93, 0.97, and 0.97 for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), respectively, with an overall pooled accuracy of 0.97 for these two groups of sonographic results. Conclusions: We concluded that AI-TIRADS has a high sensitivity and diagnostic accuracy in differentiating benign from suspicious nodules.

Shiraz E-Medical JournalVol. 25(11)
Golestan University of Medical Sciences
Openalex Percentile: Top 34%
Thyroid Cancer Diagnosis and Treatment
0.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.