<scp>Glucose‐6‐phosphate dehydrogenase</scp> deficiency detection using fluorocytometric assay: Evaluation after 1 year of clinical implementation

Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a common enzymopathy that affects red blood cells (RBCs) and renders them susceptible to oxidative stress. G6PD deficiency can cause hemolytic anemia, especially after exposure to certain drugs or infections. The diagnosis of G6PD deficiency is usually based on spectrophotometric measurement of enzyme activity, but this method has limitations in heterozygous females and in patients with other hematological disorders. In this study, we evaluated the use of flow cytometry as an alternative method for detecting G6PD deficiency in 514 samples (265 females and 249 males) from a clinical laboratory. We compared the results of flow cytometry with those of spectrophotometry and molecular analysis, and assessed the performance of flow cytometry in different subgroups of patients. We found that flow cytometry was able to identify G6PD deficiency in most cases, with high sensitivity and specificity. Flow cytometry also allowed the quantification of the percentage of G6PD-deficient RBCs, which varied among heterozygous females due to X-chromosome inactivation. Moreover, flow cytometry detected several cases of G6PD deficiency that were missed by spectrophotometry, especially in heterozygous females with normal or subnormal enzyme activity. However, flow cytometry also showed some false negative results, mainly in patients with sickle cell disease. Therefore, flow cytometry is a reliable and efficient tool for screening G6PD deficiency, but some precautions should be taken in interpreting the results in patients with other hematological conditions.

Authors

Institutions

Publication Details

Journal
Cytometry Part B Clinical Cytometry
Published
2024-10-02
DOI
https://doi.org/10.1002/cyto.b.22207
Citations
2
Primary Topic
Neonatal Health and Biochemistry
Type
article
Field-Weighted Citation Impact
2.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Glucose‐6‐phosphate dehydrogenase deficiency detection using fluorocytometric assay: Evaluation after 1 year of clinical implementation

Victor Bobée, C. Boquet, Serge Pissard, Agnès Lahary et al.
2 citations
Cytometry Part B Clinical Cytometry
Neonatal Health and Biochemistry
2.22
article

Glucose‐6‐phosphate dehydrogenase deficiency detection using fluorocytometric assay: Evaluation after 1 year of clinical implementation

Victor Bobée, C. Boquet, Serge Pissard, Agnès Lahary, Catherine Boutet, Elsa Bera, Elzette Rousseau, C. Chatellier, E. Brard, M. Souissi
article en
2 citations

Abstract

Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a common enzymopathy that affects red blood cells (RBCs) and renders them susceptible to oxidative stress. G6PD deficiency can cause hemolytic anemia, especially after exposure to certain drugs or infections. The diagnosis of G6PD deficiency is usually based on spectrophotometric measurement of enzyme activity, but this method has limitations in heterozygous females and in patients with other hematological disorders. In this study, we evaluated the use of flow cytometry as an alternative method for detecting G6PD deficiency in 514 samples (265 females and 249 males) from a clinical laboratory. We compared the results of flow cytometry with those of spectrophotometry and molecular analysis, and assessed the performance of flow cytometry in different subgroups of patients. We found that flow cytometry was able to identify G6PD deficiency in most cases, with high sensitivity and specificity. Flow cytometry also allowed the quantification of the percentage of G6PD-deficient RBCs, which varied among heterozygous females due to X-chromosome inactivation. Moreover, flow cytometry detected several cases of G6PD deficiency that were missed by spectrophotometry, especially in heterozygous females with normal or subnormal enzyme activity. However, flow cytometry also showed some false negative results, mainly in patients with sickle cell disease. Therefore, flow cytometry is a reliable and efficient tool for screening G6PD deficiency, but some precautions should be taken in interpreting the results in patients with other hematological conditions.

Cytometry Part B Clinical CytometryVol. 108(2)
Université Paris-Est Créteil (FR), Université de Rouen Normandie (FR)
Good health and well-being
Openalex Percentile: Top 11%
Neonatal Health and Biochemistry
2.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.