A new simple technique for stabilizing the guidewire position within the left ventricle during transcatheter mitral valve‐in‐valve implantation

Transcatheter mitral valve-in-valve implantation is a preferred treatment for degenerating mitral bioprosthetic valves in high-risk surgical patients. A balloon-expandable transcatheter heart valve delivered through a postero-inferior transseptal puncture is deployed within the prosthesis over a guidewire secured in the left ventricle. Patients with aneurysmal left atrium and altered angulation between the planes of atrial septum and mitral prosthesis have unstable position of the guidewire that flips out of the left ventricle into the left atrium when the valve delivery system is advanced. Instead of a transapical access to snare the guidewire and create a railroad in such instances, we report a new technique of transarterial retrograde snaring of the guidewire in the left ventricle for stabilization.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2024-10-02
DOI
https://doi.org/10.1002/ccd.31256
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A new simple technique for stabilizing the guidewire position within the left ventricle during transcatheter mitral valve‐in‐valve implantation

Puthiyedath Thejaswi, Kothandam Sivakumar, Sreeja Pavithran, Pramod Sagar
Catheterization and Cardiovascular Interventions
Cardiac Valve Diseases and Treatments
article

A new simple technique for stabilizing the guidewire position within the left ventricle during transcatheter mitral valve‐in‐valve implantation

Puthiyedath Thejaswi, Kothandam Sivakumar, Sreeja Pavithran, Pramod Sagar
article en

Abstract

Transcatheter mitral valve-in-valve implantation is a preferred treatment for degenerating mitral bioprosthetic valves in high-risk surgical patients. A balloon-expandable transcatheter heart valve delivered through a postero-inferior transseptal puncture is deployed within the prosthesis over a guidewire secured in the left ventricle. Patients with aneurysmal left atrium and altered angulation between the planes of atrial septum and mitral prosthesis have unstable position of the guidewire that flips out of the left ventricle into the left atrium when the valve delivery system is advanced. Instead of a transapical access to snare the guidewire and create a railroad in such instances, we report a new technique of transarterial retrograde snaring of the guidewire in the left ventricle for stabilization.

Catheterization and Cardiovascular InterventionsVol. 104(6)
Madras Medical Mission (IN)
Good health and well-being
Openalex Percentile: Top 70%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies