Three spectrophotometric quantitative analysis of bisoprolol fumarate and telmisartan in fixed-dose combination utilizing ratio spectra manipulation methods

Hypertension is a chronic condition with multiple drug regimens. Limiting these medicines is critical to patient compliance. Therefore, bisoprolol and telmisartan were recently developed in a fixed-dose combination to control blood pressure. The UV absorption spectra of bisoprolol and telmisartan overlapped significantly. Thus, three spectrophotometric methods have been developed for simultaneous determination of bisoprolol and telmisartan without prior separation. Method A is ratio difference of ratio spectra (RD), which measures the amplitude difference between (210-224) nm for bisoprolol and between (255-365) nm for telmisartan. Method B, the first derivative of ratio spectra (<sup>1</sup>DD), measures amplitude signals at 232 and 243 nm for bisoprolol and telmisartan, respectively. Method C is the mean centering of ratio spectra (MC), which measures the mean-centered ratio spectra's values at 223 nm for bisoprolol and 245 nm for telmisartan. The applied methods showed good linearity 2-20 µg/mL for bisoprolol, 4-32 µg/mL for telmisartan, with sufficient accuracy and precision. The methods were sensitive, with LOD values of 0.243 µg/mL and 0.596 µg/mL in RD method, 0.313 µg/mL and 0.914 µg/mL in <sup>1</sup>DD method, and 0.406 and 0.707 µg/mL in MC method for bisoprolol and telmisartan, respectively, the methods were validated per ICH criteria. The novel methods are precise and accurate and can be used for routine analysis and quality control of bisoprolol and telmisartan in pure and dosage form. Furthermore, the greenness of the approaches was evaluated using Analytical Greenness assessment (AGREE), and the suggested method received a high greenness score.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-02
DOI
https://doi.org/10.1038/s41598-024-72525-6
Citations
4
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.94

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three spectrophotometric quantitative analysis of bisoprolol fumarate and telmisartan in fixed-dose combination utilizing ratio spectra manipulation methods

Osama I. Abdel Sattar, Sherif Ramzy, Hamed H. M. Abuseada, Mahmoud M. Abuelwafa
4 citations
Scientific Reports
Analytical Methods in Pharmaceuticals
0.94
article

Three spectrophotometric quantitative analysis of bisoprolol fumarate and telmisartan in fixed-dose combination utilizing ratio spectra manipulation methods

Osama I. Abdel Sattar, Sherif Ramzy, Hamed H. M. Abuseada, Mahmoud M. Abuelwafa
article en
4 citations

Abstract

Hypertension is a chronic condition with multiple drug regimens. Limiting these medicines is critical to patient compliance. Therefore, bisoprolol and telmisartan were recently developed in a fixed-dose combination to control blood pressure. The UV absorption spectra of bisoprolol and telmisartan overlapped significantly. Thus, three spectrophotometric methods have been developed for simultaneous determination of bisoprolol and telmisartan without prior separation. Method A is ratio difference of ratio spectra (RD), which measures the amplitude difference between (210-224) nm for bisoprolol and between (255-365) nm for telmisartan. Method B, the first derivative of ratio spectra (<sup>1</sup>DD), measures amplitude signals at 232 and 243 nm for bisoprolol and telmisartan, respectively. Method C is the mean centering of ratio spectra (MC), which measures the mean-centered ratio spectra's values at 223 nm for bisoprolol and 245 nm for telmisartan. The applied methods showed good linearity 2-20 µg/mL for bisoprolol, 4-32 µg/mL for telmisartan, with sufficient accuracy and precision. The methods were sensitive, with LOD values of 0.243 µg/mL and 0.596 µg/mL in RD method, 0.313 µg/mL and 0.914 µg/mL in <sup>1</sup>DD method, and 0.406 and 0.707 µg/mL in MC method for bisoprolol and telmisartan, respectively, the methods were validated per ICH criteria. The novel methods are precise and accurate and can be used for routine analysis and quality control of bisoprolol and telmisartan in pure and dosage form. Furthermore, the greenness of the approaches was evaluated using Analytical Greenness assessment (AGREE), and the suggested method received a high greenness score.

Scientific ReportsVol. 14(1)
Al-Azhar University (EG)
Science and Technology Development Fund, Al-Azhar University
Good health and well-being
Openalex Percentile: Top 29%
Analytical Methods in Pharmaceuticals
0.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.