Design and development of knee rehabilitation robot

This research presents a comprehensive design and analysis of a knee rehabilitation platform aimed at aiding individuals with knee dysfunction. Dysfunction in the knee joint can lead to an imbalance in gait and posture during activities of daily living (ADLs) such as standing, walking, and running. This study focuses on developing a 2-degree-of-freedom (2-DoF) knee rehabilitation device capable of mimicking linear and angular movements. A slider mechanism-based knee rehabilitation device is developed and simulated alongside various other mechanisms. The proposed mechanism achieves 32.5° of flexion for a linear movement of 0.45 m within 6 seconds, outperforming other mechanisms. To validate simulation results, a 3D-printed model is fabricated, and experimental studies are conducted under no-load conditions, showing close alignment with simulation outcomes with a deviation of ±5%. The device’s key features include portability, compliance, compactness, and enhanced stiffness. Future research will involve conducting pilot studies to further evaluate the practical efficacy and potential enhancements of the proposed knee rehabilitation platform.

Authors

Institutions

Publication Details

Journal
IAES International Journal of Robotics and Automation (IJRA)
Published
2024-10-02
DOI
https://doi.org/10.11591/ijra.v13i4.pp423-431
Citations
2
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and development of knee rehabilitation robot

Devashish Sharma, Pavan Kalyan Lingampally, Sahil Ahamed Shaik, Kuppan Chetty Ramanathan et al.
2 citations
IAES International Journal of Robotics and Automation (IJRA)
Prosthetics and Rehabilitation Robotics
0.37
article

Design and development of knee rehabilitation robot

Devashish Sharma, Pavan Kalyan Lingampally, Sahil Ahamed Shaik, Kuppan Chetty Ramanathan, Manju Mohan, Saran Rajagopal
article en
2 citations

Abstract

This research presents a comprehensive design and analysis of a knee rehabilitation platform aimed at aiding individuals with knee dysfunction. Dysfunction in the knee joint can lead to an imbalance in gait and posture during activities of daily living (ADLs) such as standing, walking, and running. This study focuses on developing a 2-degree-of-freedom (2-DoF) knee rehabilitation device capable of mimicking linear and angular movements. A slider mechanism-based knee rehabilitation device is developed and simulated alongside various other mechanisms. The proposed mechanism achieves 32.5° of flexion for a linear movement of 0.45 m within 6 seconds, outperforming other mechanisms. To validate simulation results, a 3D-printed model is fabricated, and experimental studies are conducted under no-load conditions, showing close alignment with simulation outcomes with a deviation of ±5%. The device’s key features include portability, compliance, compactness, and enhanced stiffness. Future research will involve conducting pilot studies to further evaluate the practical efficacy and potential enhancements of the proposed knee rehabilitation platform.

IAES International Journal of Robotics and Automation (IJRA)Vol. 13(4)
Aston University (GB), Hindustan Institute of Technology and Science (IN), SASTRA University (IN)
Peace, Justice and strong institutions
Openalex Percentile: Top 43%
Prosthetics and Rehabilitation Robotics
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.