An active damping control strategy for suppressing LCL resonant point migration for three-phase grid-tied inverter

LCL filters are extensively utilized in Grid-connected inverters due to their exceptional capability in suppressing high-frequency harmonics. The active damping method is commonly employed to mitigate the resonance peak of the LCL filter. However, this control strategy induces a shift in the natural resonance point. To address this issue, a novel active damping control strategy based on the principle of equivalent transformation is proposed in this paper, which not only effectively suppresses the resonance peak but also avoids deviation from the natural resonance point. Finally, experiments are carried out on a three-phase LCL Grid-connected inverter, and the experimental results show that the control strategy has good steady-state performance, dynamic response, and robustness under both rigid and ultra-weak network conditions.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-02
DOI
https://doi.org/10.1038/s41598-024-73897-5
Citations
3
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.98

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An active damping control strategy for suppressing LCL resonant point migration for three-phase grid-tied inverter

Hongyi Lin, Dongdong Chen, Shengqi Zhang
3 citations
Scientific Reports
Microgrid Control and Optimization
0.98
article

An active damping control strategy for suppressing LCL resonant point migration for three-phase grid-tied inverter

Hongyi Lin, Dongdong Chen, Shengqi Zhang
article en
3 citations

Abstract

LCL filters are extensively utilized in Grid-connected inverters due to their exceptional capability in suppressing high-frequency harmonics. The active damping method is commonly employed to mitigate the resonance peak of the LCL filter. However, this control strategy induces a shift in the natural resonance point. To address this issue, a novel active damping control strategy based on the principle of equivalent transformation is proposed in this paper, which not only effectively suppresses the resonance peak but also avoids deviation from the natural resonance point. Finally, experiments are carried out on a three-phase LCL Grid-connected inverter, and the experimental results show that the control strategy has good steady-state performance, dynamic response, and robustness under both rigid and ultra-weak network conditions.

Scientific ReportsVol. 14(1)
Minnan University of Science and Technology (CN), Fuzhou University (CN), Xi'an Jiaotong University (CN)
Natural Science Foundation of Fujian Province
Reduced inequalities
Openalex Percentile: Top 23%
Microgrid Control and Optimization
0.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An active damping control strategy for suppressing LCL resonant point migration for three-phase grid-tied inverter — Hongyi Lin, Dongdong Chen, et al. · Scientific Reports (2024) | TGRS Research Map | TGRS