Under the Hood: An Easy Method for Lesions Retrieval

Endoscopic submucosal dissection (ESD) allows for effective resection of large gastrointestinal lesions with minimal risk of recurrence. The goal of ESD is to provide en bloc removal of lesions with free margins. Accurate pathological evaluation of the resected specimen is crucial for guiding patient management. In some cases, the dissected specimen is too large, hampering its retrieval through the cardia, upper esophageal sphincter or the anal canal [1]. In other cases, mostly in the colon and duodenum [2], the tissue is soft, and its retrieval can cause specimen fragmentation. Conventional endoscopic nets are useful for small or middle-size specimens but can fragment large specimens. Some other techniques were described. However, most use non-conventional devices not easily available [3, 4].Tumor extraction through defecation is a simple technique [5] but has limitations, particularly for large lesions requiring deep sedation over several hours. In these cases, immediate retrieval of the specimen is not possible, affecting pathological assessment.Herein, we describe the “under the hood” technique, using a standard endoscope to overcome this issue. This technique is easy to use and enables the retrieval of large gastrointestinal specimens intact, avoiding fragmentation. The device used is a standard bell-shaped latex tool for foreign body removal (ENDOLINE®HOOD, Prince Medical, Ercuis-France). It has a tip diameter of 8 mm and a distal diameter of 40 mm, is 75 mm long, and is easily attachable to a conventional gastroscope’s tip (shown in Fig. 1).A 60-year-old woman was referred for ESD resection of a large sigmoid colon polyp. Large size and complex morphology made margin delineation and size estimation difficult. After en bloc ESD, the specimen could not be passed through the anal canal despite several attempts with different conventional nets.We decided to use the “under the hood” technique. The hood was assembled on the tip of the 9.9 mm endoscope and inserted using lubrification. After pushing the instrument gently into the proximal rectum, the scope was slowly withdrawn to deploy the hood. Then, the specimen was gently suctioned into the hood and withdrawn. The specimen was intact, measuring 80 × 35 mm (shown in Fig. 2). Histopathologic analysis revealed an adenoma with high-grade dysplasia and free margins.The second case refers to a 68-year-old male patient who was planned for ESD resection of an 8 cm dysplastic flat lesion (Paris 0-IIb) in the proximal gastric body. It was not possible to pass the specimen through the cardia following en bloc ESD. After assembling the hood, the scope was inserted into the stomach. Afterward, the scope was withdrawn to deploy the hood, and the specimen was gently captured by suction.The scope was withdrawn with suction, retrieving a 10 cm specimen (shown in Fig. 3). Histopathologic analysis revealed an adenocarcinoma with free margins.This technique is effective regardless of specimen size and the diameter of the endoscope’s working channel. It utilizes a widely available device in most endoscopy units. However, it is contraindicated for patients with latex allergy. In conclusion, this simple, easy, cheap, and effective approach should be considered for retrieving large upper and lower gastrointestinal specimens.An informed consent was obtained from patients for publication of the details of their medical case and accompanying images. Ethical approval was not required according to local norms.No authors report potential conflicts of interest relevant to this manuscript.There were no study sponsors or funding for the study design, collection, analysis, and interpretation of the data.Execution: Francisco Baldaque-Silva, João Pereira, Leonor Guedes-Novais, and Pedro Antunes. Critically review of manuscript for intellectual content and approval of final submitted draft: Francisco Baldaque-Silva, João Pereira, Leonor Guedes-Novais, Pedro Antunes, Masami Omae, and Henrik Maltzman.João Pedro Pereira and Leonor Guedes-Novais both share first co-authorship.All relevant clinical data of this case report study are included in this article. Further inquiries can be directed to the corresponding author.

Authors

Institutions

Publication Details

Journal
GE Portuguese Journal of Gastroenterology
Published
2024-10-02
DOI
https://doi.org/10.1159/000541246
Primary Topic
Sarcoma Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Under the Hood: An Easy Method for Lesions Retrieval

Henrik Maltzman, Masami Omae, Francisco Baldaque‐Silva, Pedro E. Antunes et al.
GE Portuguese Journal of Gastroenterology
Sarcoma Diagnosis and Treatment
article

Under the Hood: An Easy Method for Lesions Retrieval

Henrik Maltzman, Masami Omae, Francisco Baldaque‐Silva, Pedro E. Antunes, João Pedro Pereira, Leonor Guedes-Novais
article en

Abstract

Endoscopic submucosal dissection (ESD) allows for effective resection of large gastrointestinal lesions with minimal risk of recurrence. The goal of ESD is to provide en bloc removal of lesions with free margins. Accurate pathological evaluation of the resected specimen is crucial for guiding patient management. In some cases, the dissected specimen is too large, hampering its retrieval through the cardia, upper esophageal sphincter or the anal canal [1]. In other cases, mostly in the colon and duodenum [2], the tissue is soft, and its retrieval can cause specimen fragmentation. Conventional endoscopic nets are useful for small or middle-size specimens but can fragment large specimens. Some other techniques were described. However, most use non-conventional devices not easily available [3, 4].Tumor extraction through defecation is a simple technique [5] but has limitations, particularly for large lesions requiring deep sedation over several hours. In these cases, immediate retrieval of the specimen is not possible, affecting pathological assessment.Herein, we describe the “under the hood” technique, using a standard endoscope to overcome this issue. This technique is easy to use and enables the retrieval of large gastrointestinal specimens intact, avoiding fragmentation. The device used is a standard bell-shaped latex tool for foreign body removal (ENDOLINE®HOOD, Prince Medical, Ercuis-France). It has a tip diameter of 8 mm and a distal diameter of 40 mm, is 75 mm long, and is easily attachable to a conventional gastroscope’s tip (shown in Fig. 1).A 60-year-old woman was referred for ESD resection of a large sigmoid colon polyp. Large size and complex morphology made margin delineation and size estimation difficult. After en bloc ESD, the specimen could not be passed through the anal canal despite several attempts with different conventional nets.We decided to use the “under the hood” technique. The hood was assembled on the tip of the 9.9 mm endoscope and inserted using lubrification. After pushing the instrument gently into the proximal rectum, the scope was slowly withdrawn to deploy the hood. Then, the specimen was gently suctioned into the hood and withdrawn. The specimen was intact, measuring 80 × 35 mm (shown in Fig. 2). Histopathologic analysis revealed an adenoma with high-grade dysplasia and free margins.The second case refers to a 68-year-old male patient who was planned for ESD resection of an 8 cm dysplastic flat lesion (Paris 0-IIb) in the proximal gastric body. It was not possible to pass the specimen through the cardia following en bloc ESD. After assembling the hood, the scope was inserted into the stomach. Afterward, the scope was withdrawn to deploy the hood, and the specimen was gently captured by suction.The scope was withdrawn with suction, retrieving a 10 cm specimen (shown in Fig. 3). Histopathologic analysis revealed an adenocarcinoma with free margins.This technique is effective regardless of specimen size and the diameter of the endoscope’s working channel. It utilizes a widely available device in most endoscopy units. However, it is contraindicated for patients with latex allergy. In conclusion, this simple, easy, cheap, and effective approach should be considered for retrieving large upper and lower gastrointestinal specimens.An informed consent was obtained from patients for publication of the details of their medical case and accompanying images. Ethical approval was not required according to local norms.No authors report potential conflicts of interest relevant to this manuscript.There were no study sponsors or funding for the study design, collection, analysis, and interpretation of the data.Execution: Francisco Baldaque-Silva, João Pereira, Leonor Guedes-Novais, and Pedro Antunes. Critically review of manuscript for intellectual content and approval of final submitted draft: Francisco Baldaque-Silva, João Pereira, Leonor Guedes-Novais, Pedro Antunes, Masami Omae, and Henrik Maltzman.João Pedro Pereira and Leonor Guedes-Novais both share first co-authorship.All relevant clinical data of this case report study are included in this article. Further inquiries can be directed to the corresponding author.

GE Portuguese Journal of GastroenterologyVol. 32(2)
Karolinska University Hospital (SE), Karolinska Institutet (SE), Hospital Pedro Hispano (PT)
Openalex Percentile: Top 69%
Sarcoma Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.