Design and Measurement of Near-Zero Thermopile RF Power Sensors for GaAs MMIC Applications

This article proposes the design and fabrication of near-zero radio frequency (RF) power sensors for GaAs monolithic microwave integrated circuit (MMIC) applications, with the principle of RF power-heat-electricity conversion. These power sensors are designed to be broadband (0.1–30 GHz), modest sensitivity (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sim 53.71~\mu $ </tex-math></inline-formula> V/mW), and low-cost manufacturing (no substrate membrane structure required). The detailed design of the near-zero RF power sensors is investigated, and the effects of the number of thermocouples and the overlap size between the resistors and the thermopile on RF and sensing performances are revealed in this article. Moreover, the fabrication is completely compatible with the GaAs MMIC technology. In addition, the measured reflection losses of the power sensors are lower than −16.3 dB up to 30 GHz. The measured sensitivities for the sensors B1, B2, C1, and C2 are 55.30, 91.00, 29.70, and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$60.29~\mu $ </tex-math></inline-formula> V/mW at 10 GHz, and 32.02, 53.71, 18.01, and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$36.63~\mu $ </tex-math></inline-formula> V/mW at 30 GHz, respectively. And the good linearity of the output responses is obtained. Experiments show that the increase of the thermocouples’ number and the overlap distance contributes to improving the sensitivities of the RF power sensors.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-10-02
DOI
https://doi.org/10.1109/jsen.2024.3468402
Citations
1
Primary Topic
Advanced Thermoelectric Materials and Devices
Type
article
Field-Weighted Citation Impact
0.12

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Measurement of Near-Zero Thermopile RF Power Sensors for GaAs MMIC Applications

Runqi Gu, Jianqiu Huang, Zhiqiang Zhang, Zijie Yuan et al.
1 citations
IEEE Sensors Journal
Advanced Thermoelectric Materials and Devices
0.12
article

Design and Measurement of Near-Zero Thermopile RF Power Sensors for GaAs MMIC Applications

Runqi Gu, Jianqiu Huang, Zhiqiang Zhang, Zijie Yuan, Meng Tang, Yuhao Xie, Sixu Lv
article en
1 citations

Abstract

This article proposes the design and fabrication of near-zero radio frequency (RF) power sensors for GaAs monolithic microwave integrated circuit (MMIC) applications, with the principle of RF power-heat-electricity conversion. These power sensors are designed to be broadband (0.1–30 GHz), modest sensitivity (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sim 53.71~\mu $ </tex-math></inline-formula> V/mW), and low-cost manufacturing (no substrate membrane structure required). The detailed design of the near-zero RF power sensors is investigated, and the effects of the number of thermocouples and the overlap size between the resistors and the thermopile on RF and sensing performances are revealed in this article. Moreover, the fabrication is completely compatible with the GaAs MMIC technology. In addition, the measured reflection losses of the power sensors are lower than −16.3 dB up to 30 GHz. The measured sensitivities for the sensors B1, B2, C1, and C2 are 55.30, 91.00, 29.70, and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$60.29~\mu $ </tex-math></inline-formula> V/mW at 10 GHz, and 32.02, 53.71, 18.01, and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$36.63~\mu $ </tex-math></inline-formula> V/mW at 30 GHz, respectively. And the good linearity of the output responses is obtained. Experiments show that the increase of the thermocouples’ number and the overlap distance contributes to improving the sensitivities of the RF power sensors.

IEEE Sensors JournalVol. 24(22)
Southeast University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 59%
Advanced Thermoelectric Materials and Devices
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.