An SPR-Based In Situ Methane Sensor for the Aqueous and Gas Phase

This paper presents a fast, low-cost, precise methane sensor based on refractive index changes in a cryptophane A (CryptA)-doped polystyrene membrane. For the realization of this sensor, we built a surface plasmon resonance sensor with a refractive index resolution of 4.31 × 10<sup>-6</sup> and investigated the optimal membrane thickness, i.e., a polymer layer of sufficient sensitivity with the lowest response time. For a membrane thickness of 760 nm, a limit of detection of 135 ppm and a response time constant of 45 s were found. Despite a comparable refractive index resolution and a higher CryptA content, the limit of detection is 3 orders of magnitude larger than that of a reported prototype. The sensor is capable of quantifying methane in the gas or aqueous phase. However, temperature, humidity, and ethanol vapor highly influence the signal. Although the principle of CryptA-based methane measurement is a promising, fast, and low-cost method, it will not be able to compete with state-of-the-art sensing in its current state.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-10-02
DOI
https://doi.org/10.1021/acs.analchem.4c02875
Citations
3
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An SPR-Based In Situ Methane Sensor for the Aqueous and Gas Phase

Philipp Harz, Arne Estelmann, Ralf D. Prien, Mark Elbing et al.
3 citations
Analytical Chemistry
Spectroscopy and Laser Applications
0.72
article

An SPR-Based In Situ Methane Sensor for the Aqueous and Gas Phase

Philipp Harz, Arne Estelmann, Ralf D. Prien, Mark Elbing, Gregor Rehder, Willem Marz
article en
3 citations

Abstract

This paper presents a fast, low-cost, precise methane sensor based on refractive index changes in a cryptophane A (CryptA)-doped polystyrene membrane. For the realization of this sensor, we built a surface plasmon resonance sensor with a refractive index resolution of 4.31 × 10<sup>-6</sup> and investigated the optimal membrane thickness, i.e., a polymer layer of sufficient sensitivity with the lowest response time. For a membrane thickness of 760 nm, a limit of detection of 135 ppm and a response time constant of 45 s were found. Despite a comparable refractive index resolution and a higher CryptA content, the limit of detection is 3 orders of magnitude larger than that of a reported prototype. The sensor is capable of quantifying methane in the gas or aqueous phase. However, temperature, humidity, and ethanol vapor highly influence the signal. Although the principle of CryptA-based methane measurement is a promising, fast, and low-cost method, it will not be able to compete with state-of-the-art sensing in its current state.

Analytical ChemistryVol. 96(41)
Leibniz Institute for Baltic Sea Research Warnemünde (DE), Technical University of Applied Sciences Lübeck (DE), University of Rostock (DE)
Leibniz-Gemeinschaft
Openalex Percentile: Top 33%
Spectroscopy and Laser Applications
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An SPR-Based In Situ Methane Sensor for the Aqueous and Gas Phase — Philipp Harz, Arne Estelmann, et al. · Analytical Chemistry (2024) | TGRS Research Map | TGRS