Quality assurance for online adaptive radiotherapy: a secondary dose verification model with geometry-encoded U-Net

In online adaptive radiotherapy (ART), quick computation-based secondary dose verification is crucial for ensuring the quality of ART plans while the patient is positioned on the treatment couch. However, traditional dose verification algorithms are generally time-consuming, reducing the efficiency of ART workflow. This study aims to develop an ultra-fast deep-learning (DL) based secondary dose verification algorithm to accurately estimate dose distributions using computed tomography (CT) and fluence maps (FMs). We integrated FMs into the CT image domain by explicitly resolving the geometry of treatment delivery. For each gantry angle, an FM was constructed based on the optimized multi-leaf collimator apertures and corresponding monitoring units. To effectively encode treatment beam configuration, the constructed FMs were back-projected to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>30</mml:mn></mml:mrow> </mml:math> cm away from the isocenter with respect to the exact geometry of the treatment machines. Then, a 3D U-Net was utilized to take the integrated CT and FM volume as input to estimate dose. Training and validation were performed on <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>381</mml:mn></mml:mrow> </mml:math> prostate cancer cases, with an additional <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>40</mml:mn></mml:mrow> </mml:math> testing cases for independent evaluation of model performance. The proposed model can estimate dose in ∼ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>15</mml:mn></mml:mrow> </mml:math> ms for each patient. The average <i>γ</i> passing rate ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>3</mml:mn> <mml:mi>%</mml:mi> <mml:mrow><mml:mo>/</mml:mo></mml:mrow> <mml:mn>2</mml:mn> <mml:mstyle></mml:mstyle> <mml:mrow><mml:mtext>mm</mml:mtext></mml:mrow> </mml:mrow> </mml:math> , <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>10</mml:mn> <mml:mi>%</mml:mi></mml:mrow> </mml:math> threshold) for the estimated dose was 99.9% ± 0.15% on testing patients. The mean dose differences for the planning target volume and organs at risk were <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>0.07</mml:mn> <mml:mi>%</mml:mi> <mml:mo>±</mml:mo> <mml:mn>0.34</mml:mn> <mml:mi>%</mml:mi></mml:mrow> </mml:math> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>0.48</mml:mn> <mml:mi>%</mml:mi> <mml:mo>±</mml:mo> <mml:mn>0.72</mml:mn> <mml:mi>%</mml:mi></mml:mrow> </mml:math> , respectively. We have developed a geometry-resolved DL framework for accurate dose estimation and demonstrated its potential in real-time online ART doses verification.

Authors

Institutions

Publication Details

Journal
Machine Learning Science and Technology
Published
2024-10-02
DOI
https://doi.org/10.1088/2632-2153/ad829e
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quality assurance for online adaptive radiotherapy: a secondary dose verification model with geometry-encoded U-Net

Chenyang Shen, Steve Jiang, Biling Wang, Dan Nguyen et al.
1 citations
Machine Learning Science and Technology
Advanced Radiotherapy Techniques
0.61
article

Quality assurance for online adaptive radiotherapy: a secondary dose verification model with geometry-encoded U-Net

Chenyang Shen, Steve Jiang, Biling Wang, Dan Nguyen, Austen Maniscalco, Shunyu Yan
article en
1 citations

Abstract

In online adaptive radiotherapy (ART), quick computation-based secondary dose verification is crucial for ensuring the quality of ART plans while the patient is positioned on the treatment couch. However, traditional dose verification algorithms are generally time-consuming, reducing the efficiency of ART workflow. This study aims to develop an ultra-fast deep-learning (DL) based secondary dose verification algorithm to accurately estimate dose distributions using computed tomography (CT) and fluence maps (FMs). We integrated FMs into the CT image domain by explicitly resolving the geometry of treatment delivery. For each gantry angle, an FM was constructed based on the optimized multi-leaf collimator apertures and corresponding monitoring units. To effectively encode treatment beam configuration, the constructed FMs were back-projected to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>30</mml:mn></mml:mrow> </mml:math> cm away from the isocenter with respect to the exact geometry of the treatment machines. Then, a 3D U-Net was utilized to take the integrated CT and FM volume as input to estimate dose. Training and validation were performed on <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>381</mml:mn></mml:mrow> </mml:math> prostate cancer cases, with an additional <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>40</mml:mn></mml:mrow> </mml:math> testing cases for independent evaluation of model performance. The proposed model can estimate dose in ∼ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>15</mml:mn></mml:mrow> </mml:math> ms for each patient. The average <i>γ</i> passing rate ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>3</mml:mn> <mml:mi>%</mml:mi> <mml:mrow><mml:mo>/</mml:mo></mml:mrow> <mml:mn>2</mml:mn> <mml:mstyle></mml:mstyle> <mml:mrow><mml:mtext>mm</mml:mtext></mml:mrow> </mml:mrow> </mml:math> , <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>10</mml:mn> <mml:mi>%</mml:mi></mml:mrow> </mml:math> threshold) for the estimated dose was 99.9% ± 0.15% on testing patients. The mean dose differences for the planning target volume and organs at risk were <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>0.07</mml:mn> <mml:mi>%</mml:mi> <mml:mo>±</mml:mo> <mml:mn>0.34</mml:mn> <mml:mi>%</mml:mi></mml:mrow> </mml:math> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>0.48</mml:mn> <mml:mi>%</mml:mi> <mml:mo>±</mml:mo> <mml:mn>0.72</mml:mn> <mml:mi>%</mml:mi></mml:mrow> </mml:math> , respectively. We have developed a geometry-resolved DL framework for accurate dose estimation and demonstrated its potential in real-time online ART doses verification.

Machine Learning Science and TechnologyVol. 5(4)
The University of Texas Southwestern Medical Center (US)
National Institutes of Health
Openalex Percentile: Top 31%
Advanced Radiotherapy Techniques
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.