Growth of nanocrystalline graphite and vertically aligned graphite nanowalls thin films and their transfer on flexible substrates for applications as electrochemical sensors for anthracene detection

• PECVD growth of N-doped NCG and GNW films was realized on Si and Cu substrate. • GNW film showed better crystallinity and more sp 2 C content than the N-NCG film. • The carbonic materials were transferred on flexible polyethylene substrate. • GNW/PE showed the best electrochemical sensing ability for anthracene detection. Plasma-enhanced chemical vapor deposition (PECVD) allows the growth of nanocrystalline graphite (NCG)-type materials, such as N-doped bulk NCG and graphite nanowalls (GNW), on different substrates (silicon and copper) to develop flexible electrochemical sensors for anthracene detection. The carbonic materials were investigated using different techniques, including X-ray diffraction, small-angle X-ray scattering, scanning electron microscopy, X-ray photoelectron spectroscopy, cyclic voltammetry, and differential pulsed voltammetry (DPV). XRD analysis revealed different crystallinity features for both graphitic materials, as the N-NCG film presented higher lattice strain (1 %) and dislocation density (5.2 × 10 12 cm −2 ), compared to the GNW film with a lattice strain of 0.2 % and dislocation density of 7 × 10 11 cm −2 . We also present a successful approach for developing flexible electrodes via transfer process from Cu to polyethylene (PE) substrate. The carbonic films were transferred onto flexible substrates via thermal treatment of the Cu foils with the PE layers, followed by Cu etching to reveal the carbon material as the sensing area of the flexible sensors. Electrodes based on N-NCG and GNW grown on silicon and those transferred to PE substrates were investigated at different anthracene concentrations by DPV. The results showed greater performance for anthracene determination in the case of N-NCG/Si, showing a sensibility of 0.8 A⋅M −1 than that of GNW/Si (0.0625 A⋅M −1 ). However, the flexible GNW/PE electrode exhibited an increased response in DPV in the presence of anthracene, resulting in a higher sensitivity (0.23 A⋅M −1 ) than that of N-NCG/PE (0.19 A⋅M −1 ). This behavior suggests the good electrochemical compatibility of the GNW film with the flexible polymeric substrate to obtain a flexible electrochemical sensor for anthracene detection.

Authors

Institutions

Publication Details

Journal
Microchemical Journal
Published
2024-10-02
DOI
https://doi.org/10.1016/j.microc.2024.111828
Citations
6
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Growth of nanocrystalline graphite and vertically aligned graphite nanowalls thin films and their transfer on flexible substrates for applications as electrochemical sensors for anthracene detection

Antonio Radoi, Cosmin Romanițan, Oana Brîncoveanu, Octavian‐Gabriel Simionescu et al.
6 citations
Microchemical Journal
Electrochemical sensors and biosensors
1.25
article

Growth of nanocrystalline graphite and vertically aligned graphite nanowalls thin films and their transfer on flexible substrates for applications as electrochemical sensors for anthracene detection

Antonio Radoi, Cosmin Romanițan, Oana Brîncoveanu, Octavian‐Gabriel Simionescu, Marius Stoian, Adrian Dinescu, N. Djourelov
article en
6 citations

Abstract

• PECVD growth of N-doped NCG and GNW films was realized on Si and Cu substrate. • GNW film showed better crystallinity and more sp 2 C content than the N-NCG film. • The carbonic materials were transferred on flexible polyethylene substrate. • GNW/PE showed the best electrochemical sensing ability for anthracene detection. Plasma-enhanced chemical vapor deposition (PECVD) allows the growth of nanocrystalline graphite (NCG)-type materials, such as N-doped bulk NCG and graphite nanowalls (GNW), on different substrates (silicon and copper) to develop flexible electrochemical sensors for anthracene detection. The carbonic materials were investigated using different techniques, including X-ray diffraction, small-angle X-ray scattering, scanning electron microscopy, X-ray photoelectron spectroscopy, cyclic voltammetry, and differential pulsed voltammetry (DPV). XRD analysis revealed different crystallinity features for both graphitic materials, as the N-NCG film presented higher lattice strain (1 %) and dislocation density (5.2 × 10 12 cm −2 ), compared to the GNW film with a lattice strain of 0.2 % and dislocation density of 7 × 10 11 cm −2 . We also present a successful approach for developing flexible electrodes via transfer process from Cu to polyethylene (PE) substrate. The carbonic films were transferred onto flexible substrates via thermal treatment of the Cu foils with the PE layers, followed by Cu etching to reveal the carbon material as the sensing area of the flexible sensors. Electrodes based on N-NCG and GNW grown on silicon and those transferred to PE substrates were investigated at different anthracene concentrations by DPV. The results showed greater performance for anthracene determination in the case of N-NCG/Si, showing a sensibility of 0.8 A⋅M −1 than that of GNW/Si (0.0625 A⋅M −1 ). However, the flexible GNW/PE electrode exhibited an increased response in DPV in the presence of anthracene, resulting in a higher sensitivity (0.23 A⋅M −1 ) than that of N-NCG/PE (0.19 A⋅M −1 ). This behavior suggests the good electrochemical compatibility of the GNW film with the flexible polymeric substrate to obtain a flexible electrochemical sensor for anthracene detection.

Microchemical JournalVol. 207
University of Bucharest (RO), Institute of Catalysis and Petrochemistry (RU), National Institute for Research and Development in Microtechnologies (RO), Extreme Light Infrastructure - Nuclear Physics (RO)
Unitatea Executiva pentru Finantarea Invatamantului Superior, a Cercetarii, Dezvoltarii si Inovarii
Openalex Percentile: Top 20%
Electrochemical sensors and biosensors
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.