Efficacy of sevoflurane flush out and activated charcoal filtration—a bench study

Abstract Purpose A bench study to assess the elimination of sevoflurane from an anesthetic workstation using three different processing methods. Methods Sevoflurane concentrations from samples of the inspiratory breathing hose and air samples from within the investigation room were assessed during predetermined flush out intervals using Gas Chromatography-Ion Mobility Spectrometry. The primary objective was to determine the time to reach concentrations below 5 ppm v . Results Reduction of sevoflurane volume concentrations below a threshold of 5 ppm v was achieved within the first minute after removal of the vaporizer and the complete exchange of the soda and the breathing system and within the 15 min measurement interval after inclusion of two activated charcoal filters without a 90 s of flushing and without changing of the breathing hoses as required by the manufacturer. Conclusions Complete removal of the vaporizer and an exchange of the soda and the ventilation unit most quickly reduced sevoflurane concentrations, but the total processing interval may exceed 30 min. Inserted activated charcoal filters without a previous 90 s of flushing and without changing the breathing hoses followed by flushing only with raised fresh gas flow allow ventilation below trigger threshold to be reached within due time.

Authors

Institutions

Publication Details

Journal
Anesthesiology and Perioperative Science
Published
2024-10-02
DOI
https://doi.org/10.1007/s44254-024-00072-4
Citations
2
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy of sevoflurane flush out and activated charcoal filtration—a bench study

Chris A. Mayhew, Florentin Weiss, Anesu Chawaguta, Helmut Wiesenhofer et al.
2 citations
Anesthesiology and Perioperative Science
Infection Control and Ventilation
0.84
article

Efficacy of sevoflurane flush out and activated charcoal filtration—a bench study

Chris A. Mayhew, Florentin Weiss, Anesu Chawaguta, Helmut Wiesenhofer, Veronika Ruzsányi, Wolfgang Lederer, Daniel Schwaiger, Maximilian Mörtl
article en
2 citations

Abstract

Abstract Purpose A bench study to assess the elimination of sevoflurane from an anesthetic workstation using three different processing methods. Methods Sevoflurane concentrations from samples of the inspiratory breathing hose and air samples from within the investigation room were assessed during predetermined flush out intervals using Gas Chromatography-Ion Mobility Spectrometry. The primary objective was to determine the time to reach concentrations below 5 ppm v . Results Reduction of sevoflurane volume concentrations below a threshold of 5 ppm v was achieved within the first minute after removal of the vaporizer and the complete exchange of the soda and the breathing system and within the 15 min measurement interval after inclusion of two activated charcoal filters without a 90 s of flushing and without changing of the breathing hoses as required by the manufacturer. Conclusions Complete removal of the vaporizer and an exchange of the soda and the ventilation unit most quickly reduced sevoflurane concentrations, but the total processing interval may exceed 30 min. Inserted activated charcoal filters without a previous 90 s of flushing and without changing the breathing hoses followed by flushing only with raised fresh gas flow allow ventilation below trigger threshold to be reached within due time.

Anesthesiology and Perioperative ScienceVol. 2(4)
Innsbruck Medical University (AT), Universität Innsbruck (AT)
Clean water and sanitation
Openalex Percentile: Top 24%
Infection Control and Ventilation
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Efficacy of sevoflurane flush out and activated charcoal filtration—a bench study — Chris A. Mayhew, Florentin Weiss, et al. · Anesthesiology and Perioperative Science (2024) | TGRS Research Map | TGRS