Dynamic Liver Chip Based on Well-Coupled Microfluidics: An Accurate NASH Model for Drug Evaluation

The convenient liver model in vitro recapitulating the hepatic functions, metabolism, and even steatohepatitis to perform the accurate drug evaluation is still challenging because of the unattainable hominine physiological microenvironment in vitro. Here, the progressed stages of nonalcoholic steatohepatitis (NASH) disease were precisely modeled to accurately evaluate the performance of antilipemic based on the dynamic liver chip adopting the well-coupled microfluidics, which well recapitulated the normal and steatohepatitis of liver in vitro. In brief, the mild nutrient flow and sufficient oxygen supply for parenchymal liver cells could be well supplied through the endothelial cells layer that mimicked the real physiological barrier of endothelium, while the loading of drugs might be obtained by directly adding drug into the running nutrient flow to mimic the intravenously administrable. The progressed degree of steatohepatitis could be directly reflected by the amount of intramyocellular lipid content (IMLC) of the HepG2 cell hepatocyte layer in wells that were induced by different concentrations of free fatty acids (FFA). To prove the concept of the liver chip in drug evaluation, an accurate assessment of the performance of firsocostat, the acetyl-CoA carboxylase (ACC) inhibitor of hepatic mitochondria of hepatocytes, was carried out. The subtle time dependence of firsocostat treatment to different progressed stages of NASH was clearly figured out. Therefore, we prospect the liver chip that adopted well-coupled microfluidics could be an accurate and standard liver model in vitro to carry out the antilipemic evaluation and screening, which significantly enlightens the drug evaluation by liver on chip in vitro.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-10-02
DOI
https://doi.org/10.1021/acs.analchem.4c03234
Citations
7
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
1.29

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Liver Chip Based on Well-Coupled Microfluidics: An Accurate NASH Model for Drug Evaluation

Bingqian Liu, Hulie Zeng, Ming‐Yang Chang, Anchen Fu et al.
7 citations
Analytical Chemistry
3D Printing in Biomedical Research
1.29
article

Dynamic Liver Chip Based on Well-Coupled Microfluidics: An Accurate NASH Model for Drug Evaluation

Bingqian Liu, Hulie Zeng, Ming‐Yang Chang, Anchen Fu, Yongxiang Wang
article en
7 citations

Abstract

The convenient liver model in vitro recapitulating the hepatic functions, metabolism, and even steatohepatitis to perform the accurate drug evaluation is still challenging because of the unattainable hominine physiological microenvironment in vitro. Here, the progressed stages of nonalcoholic steatohepatitis (NASH) disease were precisely modeled to accurately evaluate the performance of antilipemic based on the dynamic liver chip adopting the well-coupled microfluidics, which well recapitulated the normal and steatohepatitis of liver in vitro. In brief, the mild nutrient flow and sufficient oxygen supply for parenchymal liver cells could be well supplied through the endothelial cells layer that mimicked the real physiological barrier of endothelium, while the loading of drugs might be obtained by directly adding drug into the running nutrient flow to mimic the intravenously administrable. The progressed degree of steatohepatitis could be directly reflected by the amount of intramyocellular lipid content (IMLC) of the HepG2 cell hepatocyte layer in wells that were induced by different concentrations of free fatty acids (FFA). To prove the concept of the liver chip in drug evaluation, an accurate assessment of the performance of firsocostat, the acetyl-CoA carboxylase (ACC) inhibitor of hepatic mitochondria of hepatocytes, was carried out. The subtle time dependence of firsocostat treatment to different progressed stages of NASH was clearly figured out. Therefore, we prospect the liver chip that adopted well-coupled microfluidics could be an accurate and standard liver model in vitro to carry out the antilipemic evaluation and screening, which significantly enlightens the drug evaluation by liver on chip in vitro.

Analytical ChemistryVol. 96(41)
Guizhou University (CN), Fudan University (CN), Shanghai University of Traditional Chinese Medicine (CN), Shuguang Hospital (CN)
Shanghai Science and Technology Development Foundation, National Natural Science Foundation of China
Openalex Percentile: Top 21%
3D Printing in Biomedical Research
1.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.