Electrochemical biosensing of cerium with a tyrosine‐functionalized <scp>EF</scp>‐hand loop peptide

Abstract The significance of easily detecting rare earth elements (REEs) has increased due to the growing demand for REEs. Addressing this need, we present an innovative electrochemical biosensor, focusing on cerium as a model REE. This biosensor utilizes a modified EF‐hand loop peptide sequence, incorporating cysteine for covalent attachment to a gold working electrode and tyrosine as an electrochemically active amino acid. The sensor was designed such that binding to cerium induces a conformational change in the peptide, affecting tyrosine's proximity to the electrode surface, modulating the current. A calibration curve was generated from cyclic voltammetry current peaks at ~0.55–0.65 V versus a silver pseudo‐reference electrode, with cerium concentrations ranging from 0 to 67 μM in artificial urine. The sensor exhibited a biologically relevant limit of detection of 35 μM and a sensitivity of −0.0024 ± 0.002 (μA μM) −1 . These findings offer insights into designing peptide sequences for electrochemical biosensing.

Authors

Institutions

Publication Details

Journal
AIChE Journal
Published
2024-10-02
DOI
https://doi.org/10.1002/aic.18620
Citations
3
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical biosensing of cerium with a tyrosine‐functionalized EF‐hand loop peptide

Julie Renner, Sogol Asaei, Geeta Verma, Nicholas Scott Sinclair
3 citations
AIChE Journal
Advanced biosensing and bioanalysis techniques
0.70
article

Electrochemical biosensing of cerium with a tyrosine‐functionalized EF‐hand loop peptide

Julie Renner, Sogol Asaei, Geeta Verma, Nicholas Scott Sinclair
article en
3 citations

Abstract

Abstract The significance of easily detecting rare earth elements (REEs) has increased due to the growing demand for REEs. Addressing this need, we present an innovative electrochemical biosensor, focusing on cerium as a model REE. This biosensor utilizes a modified EF‐hand loop peptide sequence, incorporating cysteine for covalent attachment to a gold working electrode and tyrosine as an electrochemically active amino acid. The sensor was designed such that binding to cerium induces a conformational change in the peptide, affecting tyrosine's proximity to the electrode surface, modulating the current. A calibration curve was generated from cyclic voltammetry current peaks at ~0.55–0.65 V versus a silver pseudo‐reference electrode, with cerium concentrations ranging from 0 to 67 μM in artificial urine. The sensor exhibited a biologically relevant limit of detection of 35 μM and a sensitivity of −0.0024 ± 0.002 (μA μM) −1 . These findings offer insights into designing peptide sequences for electrochemical biosensing.

AIChE JournalVol. 70(12)
Case Western Reserve University (US)
National Science Foundation, Cleveland Clinic
Openalex Percentile: Top 29%
Advanced biosensing and bioanalysis techniques
0.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.