<p><strong>The use of electric motors in industry often experiences damage caused by several things, including high <em>starting</em> current surges, overload or full load, loss of one phase in the electric motor, and other causes of damage to the 3-phase motor. The main problem that occurred in this research was damage caused by high <em>starting</em> currents, where in the case study many 3-phase motors were used to drive factory machines. The use of 3-phase motors to drive factory machines is often damaged by unstable currents in the machines. This is because the time and workers for monitoring are very minimal and the materials for repairing machines are inadequate. In this way, the solution for repairing a 3-phase motor is to replace and rewind the damaged motor so that it can be used again. This research aims to find a solution on how to reduce high <em>starting</em> currents in 3-phase motors by utilizing the influence of replacing damaged induction motor components as well as repair methods used in <em>starting</em> when <em>rewinding</em> 3-phase motors. The research results from the groove distance with a wire size of 0.90 mm showed that the groove distance of 9, 9, 8 was 29.3, and at a distance of 10, 10, 10 it had a current of 31 A with no-load testing and recommended groove distances of 10, 10, 10. Next, testing wire sizes of 0.75 mm and 0.90 mm with distances of 10, 10, 10, and 9, 9, 8 without load obtained 26.1 A and 27.4 A while 0.90 mm was 30, 7 A and 28, 1 A. The load was 43.5 A and 43.9 A, while 0.90 mm was 51.3 A and 49.3 A. From the test results, the largest current decrease was at a distance of 10, 10, 10 with a wire size of 0.75 mm. </strong></p><p><strong>Keyword - <em>3 Phase Induction Motor, Groove Spacing, Starting, Wire Size.</em></strong></p>

Authors

Institutions

Publication Details

Journal
JURNAL Al-AZHAR INDONESIA SERI SAINS DAN TEKNOLOGI
Published
2024-09-20
DOI
https://doi.org/10.36722/sst.v9i3.2868
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pengaruh Ukuran Kawat dan Jarak Alur Stator Terhadap Nilai Arus Starting Motor Induksi 3 Fasa

Fran Hendrick, Liliana Liliana
JURNAL Al-AZHAR INDONESIA SERI SAINS DAN TEKNOLOGI
Engineering and Technology Innovations
article

Pengaruh Ukuran Kawat dan Jarak Alur Stator Terhadap Nilai Arus Starting Motor Induksi 3 Fasa

Fran Hendrick, Liliana Liliana
article en

Abstract

<p><strong>The use of electric motors in industry often experiences damage caused by several things, including high <em>starting</em> current surges, overload or full load, loss of one phase in the electric motor, and other causes of damage to the 3-phase motor. The main problem that occurred in this research was damage caused by high <em>starting</em> currents, where in the case study many 3-phase motors were used to drive factory machines. The use of 3-phase motors to drive factory machines is often damaged by unstable currents in the machines. This is because the time and workers for monitoring are very minimal and the materials for repairing machines are inadequate. In this way, the solution for repairing a 3-phase motor is to replace and rewind the damaged motor so that it can be used again. This research aims to find a solution on how to reduce high <em>starting</em> currents in 3-phase motors by utilizing the influence of replacing damaged induction motor components as well as repair methods used in <em>starting</em> when <em>rewinding</em> 3-phase motors. The research results from the groove distance with a wire size of 0.90 mm showed that the groove distance of 9, 9, 8 was 29.3, and at a distance of 10, 10, 10 it had a current of 31 A with no-load testing and recommended groove distances of 10, 10, 10. Next, testing wire sizes of 0.75 mm and 0.90 mm with distances of 10, 10, 10, and 9, 9, 8 without load obtained 26.1 A and 27.4 A while 0.90 mm was 30, 7 A and 28, 1 A. The load was 43.5 A and 43.9 A, while 0.90 mm was 51.3 A and 49.3 A. From the test results, the largest current decrease was at a distance of 10, 10, 10 with a wire size of 0.75 mm. </strong></p><p><strong>Keyword - <em>3 Phase Induction Motor, Groove Spacing, Starting, Wire Size.</em></strong></p>

JURNAL Al-AZHAR INDONESIA SERI SAINS DAN TEKNOLOGIVol. 9(3)
Universitas Islam Negeri Sultan Syarif Kasim Riau (ID)
Openalex Percentile: Top 86%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.