Analysis of the results of optical coherence tomography to assess the effectiveness and safety of implantable bioresorbable stenting frames in the long term

Objective : to evaluate the effectiveness and safety of implantation of everolimus-coated bioabsorbable vascular scaffolds (BSCs) based on the results of optical coherence tomography (OCT) in patients with coronary artery disease who have previously undergone percutaneous coronary intervention (PCI). Materials and methods: OCT data from 23 patients with coronary artery disease (CAD) were studied 10 years or more after intervention with BVS implantation. Standard criteria based on OCT analysis were used to evaluate the efficacy of BVS. The stented segment, proximal zone before the stent, and distal zone after the stent were the areas of interest. Results: in the long-term period, the structure of the artery in the area of the installed biodegradable scaffolds is a combination of fragments of an atherosclerotic plaque, a resorbed scaffold, and neointima. When visualized using coherence tomography, this structure appears as a monolayer with high signal intensity. In 42.3% of patients, structures similar to fragments of the stenting frame were visualized, but smaller in size, with a disconnected structure, without clear contours and the absence of a typical shape. In 15.4% of cases, pronounced positive remodeling of the coronary artery in the area of the installation of the bioresorbable frame was noted. Conclusions: analysis of coherence tomography data showed that the use of biodegradable frames is effective and safe, the process of degradation of the frames occurs with an increase in diameter in the stented zone and the formation of a protective monolayer, while maintaining the patency of all side branches in the implantation zone.

Authors

Publication Details

Journal
South Russian Journal of Therapeutic Practice
Published
2024-09-27
DOI
https://doi.org/10.21886/2712-8156-2024-5-3-54-61
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the results of optical coherence tomography to assess the effectiveness and safety of implantable bioresorbable stenting frames in the long term

Mikhail Vladimirovich Malevanny, E. V. Tadieva, D. S. Strokov, A. V. Hripun
South Russian Journal of Therapeutic Practice
Coronary Interventions and Diagnostics
article

Analysis of the results of optical coherence tomography to assess the effectiveness and safety of implantable bioresorbable stenting frames in the long term

Mikhail Vladimirovich Malevanny, E. V. Tadieva, D. S. Strokov, A. V. Hripun
article en

Abstract

Objective : to evaluate the effectiveness and safety of implantation of everolimus-coated bioabsorbable vascular scaffolds (BSCs) based on the results of optical coherence tomography (OCT) in patients with coronary artery disease who have previously undergone percutaneous coronary intervention (PCI). Materials and methods: OCT data from 23 patients with coronary artery disease (CAD) were studied 10 years or more after intervention with BVS implantation. Standard criteria based on OCT analysis were used to evaluate the efficacy of BVS. The stented segment, proximal zone before the stent, and distal zone after the stent were the areas of interest. Results: in the long-term period, the structure of the artery in the area of the installed biodegradable scaffolds is a combination of fragments of an atherosclerotic plaque, a resorbed scaffold, and neointima. When visualized using coherence tomography, this structure appears as a monolayer with high signal intensity. In 42.3% of patients, structures similar to fragments of the stenting frame were visualized, but smaller in size, with a disconnected structure, without clear contours and the absence of a typical shape. In 15.4% of cases, pronounced positive remodeling of the coronary artery in the area of the installation of the bioresorbable frame was noted. Conclusions: analysis of coherence tomography data showed that the use of biodegradable frames is effective and safe, the process of degradation of the frames occurs with an increase in diameter in the stented zone and the formation of a protective monolayer, while maintaining the patency of all side branches in the implantation zone.

South Russian Journal of Therapeutic PracticeVol. 5(3)
Openalex Percentile: Top 68%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of the results of optical coherence tomography to assess the effectiveness and safety of implantable bioresorbable stenting frames in the long term — Mikhail Vladimirovich Malevanny, E. V. Tadieva, et al. · South Russian Journal of Therapeutic Practice (2024) | TGRS Research Map | TGRS