Analysis and protection strategy based on Modular Multilevel Converter Direct Current faults

This paper conducts in-depth research on the topology structure, working principle, and modulation methods of Modular Multilevel Converter (MMC), providing theoretical support to examine the fault traits on the Direct Current (DC) side. The paper focuses on analyzing the typical DC side faults within the modular multilevel converter-based high-voltage direct current (MMC-HVDC) system and validates the analysis results of DC side faults through simulation using the PSCAD/EMTDC simulation platform. It also proposes a Full-Bridge Modular Multilevel Converter (FBMMC) topology structure that effectively controls the energy exchange during the DC side fault by introducing a submodule capacitor in the bridge arm.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/spic62469.2024.10691434
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and protection strategy based on Modular Multilevel Converter Direct Current faults

Hao Sha, Ruihao Wang, Chen Gao, Ruming Feng
HVDC Systems and Fault Protection
article

Analysis and protection strategy based on Modular Multilevel Converter Direct Current faults

Hao Sha, Ruihao Wang, Chen Gao, Ruming Feng
article en

Abstract

This paper conducts in-depth research on the topology structure, working principle, and modulation methods of Modular Multilevel Converter (MMC), providing theoretical support to examine the fault traits on the Direct Current (DC) side. The paper focuses on analyzing the typical DC side faults within the modular multilevel converter-based high-voltage direct current (MMC-HVDC) system and validates the analysis results of DC side faults through simulation using the PSCAD/EMTDC simulation platform. It also proposes a Full-Bridge Modular Multilevel Converter (FBMMC) topology structure that effectively controls the energy exchange during the DC side fault by introducing a submodule capacitor in the bridge arm.

Shenyang Ligong University (CN), Inner Mongolia Electric Power (China) (CN)
Technology Development
Climate action
Openalex Percentile: Top 86%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis and protection strategy based on Modular Multilevel Converter Direct Current faults — Hao Sha, Ruihao Wang, et al. · (2024) | TGRS Research Map | TGRS