On the accuracy of the segmentation process and transcatheter heart valve dimensions in TAVI patients

Accurate segmentation of medical images is critical for generating patient-specific models suitable for computational analyses, particularly in the context of transcatheter aortic valve implantation (TAVI). This study aimed to quantify the accuracy of the segmentation process from medical images of TAVI patients to understand the uncertainty in patient-specific geometries. We also quantified discrepancies between actual and CT-related diameter measurements due to artifacts and intra-observer variability. Segmentation accuracy was assessed using both synthetic phantom models and patient-specific data. The impact of voxelization and CT scanner resolution on segmentation accuracy was evaluated, while the intersection over union (IoU) metric was used to compare the consistency of different segmentation methodologies. The voxelization process introduced a marginal error (<1%) in phantom models relative to CAD models. CT scanner resolution impacted segmented model accuracy only after a 7.5-fold increase in voxel size compared to the baseline medical image. IoU analysis revealed higher segmentation accuracy for calcification (93.4 ± 3.1 %) compared to the aortic wall (85.4 ± 8.4 %) and native valve leaflets (75.5 ± 6.3 %). Discrepancies in THV diameter measurements highlighted a ∼5 % error due to metallic artifacts, with variability among observers and at different THV heights. Errors due to voxel size, segmentation methodologies and CT-related artifacts can impact the reliability of patient-specific geometries and ultimately computational predictions used to asses clinical outcomes and enhance decision-making. This study underscores the importance of accurate segmentation and its standardization for patient-specific modeling of TAVI simulations.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2024-10-02
DOI
https://doi.org/10.1016/j.jbiomech.2024.112357
Citations
3
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the accuracy of the segmentation process and transcatheter heart valve dimensions in TAVI patients

Caterina Maria Gandolfo, Diego Bellavia, Stefano Cannata, Salvatore Pasta et al.
3 citations
Journal of Biomechanics
Cardiac Valve Diseases and Treatments
1.21
article

On the accuracy of the segmentation process and transcatheter heart valve dimensions in TAVI patients

Caterina Maria Gandolfo, Diego Bellavia, Stefano Cannata, Salvatore Pasta, Roberta Scuoppo
article en
3 citations

Abstract

Accurate segmentation of medical images is critical for generating patient-specific models suitable for computational analyses, particularly in the context of transcatheter aortic valve implantation (TAVI). This study aimed to quantify the accuracy of the segmentation process from medical images of TAVI patients to understand the uncertainty in patient-specific geometries. We also quantified discrepancies between actual and CT-related diameter measurements due to artifacts and intra-observer variability. Segmentation accuracy was assessed using both synthetic phantom models and patient-specific data. The impact of voxelization and CT scanner resolution on segmentation accuracy was evaluated, while the intersection over union (IoU) metric was used to compare the consistency of different segmentation methodologies. The voxelization process introduced a marginal error (<1%) in phantom models relative to CAD models. CT scanner resolution impacted segmented model accuracy only after a 7.5-fold increase in voxel size compared to the baseline medical image. IoU analysis revealed higher segmentation accuracy for calcification (93.4 ± 3.1 %) compared to the aortic wall (85.4 ± 8.4 %) and native valve leaflets (75.5 ± 6.3 %). Discrepancies in THV diameter measurements highlighted a ∼5 % error due to metallic artifacts, with variability among observers and at different THV heights. Errors due to voxel size, segmentation methodologies and CT-related artifacts can impact the reliability of patient-specific geometries and ultimately computational predictions used to asses clinical outcomes and enhance decision-making. This study underscores the importance of accurate segmentation and its standardization for patient-specific modeling of TAVI simulations.

Journal of BiomechanicsVol. 176
Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione (IT), University of Palermo (IT)
H2020 Excellent Science
Zero hunger
Openalex Percentile: Top 18%
Cardiac Valve Diseases and Treatments
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.