Modification of Screen-Printed Carbon Electrode with Nanogold for Detection of Glucose

The properties of screen-printed carbon electrodes (SPCE) with nanogold (AuNP) were ascertained to detect glucose samples.The electrodes were modified with different potentials to obtain suitable potentials for the detection of glucose.The potentials used to prepare gold electrodes were -0.8 V, +0.56 V, and +0.9 V.The bare SPCE acted as a comparison between the bare and the modified SPCE.The modified electrodes (AuNP/SPCE) were characterised using Field Emission Scanning Electron Microscopy (FESEM), Energy Dispersive X-ray (EDX), and X-ray Diffraction (XRD) with deposition at -0.8 V and +0.56 V, proving that the gold nanostructures were deposited at the SPCE surface.The deposition at +0.9 V had an insignificant amount of Au on the SPCE surface, similar to bare SPCE.The active sites and reversibility of the gold electrode can be determined by measuring the electrochemical active surface area (ECSA) of electrode and its anodic and cathodic peak current density ratio (Ipa/Ipc), respectively.The ECSA for modified SPCE with different potentials of -0.8 V, +0.56 V, and +0.9 V were 6.873 cm 2 , 0.786 cm 2 , and 0.253 cm 2 , respectively.The Ipa/Ipc ratio of +0.56 V and -0.8 V showed excellent reversibility and transfer rate compared to +0.9 V. Thus, deposition at -0.8 V and +0.56 V was chosen to detect glucose, and the sensitivity and limit of detection (LOD) were calculated.The sensitivity and LOD for these two modified electrodes (-0.8 V and +0.56 V) were 7.53 mA.mM -1 cm -2 and 14.73 mM, as well as 73.38 mA.mM -1 cm -2 and 13.13 mM, respectively.

Publication Details

Journal
Malaysian Journal of Chemistry
Published
2024-10-02
DOI
https://doi.org/10.55373/mjchem.v26i5.90
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modification of Screen-Printed Carbon Electrode with Nanogold for Detection of Glucose

Malaysian Journal of Chemistry
Electrochemical sensors and biosensors
article

Modification of Screen-Printed Carbon Electrode with Nanogold for Detection of Glucose

article en

Abstract

The properties of screen-printed carbon electrodes (SPCE) with nanogold (AuNP) were ascertained to detect glucose samples.The electrodes were modified with different potentials to obtain suitable potentials for the detection of glucose.The potentials used to prepare gold electrodes were -0.8 V, +0.56 V, and +0.9 V.The bare SPCE acted as a comparison between the bare and the modified SPCE.The modified electrodes (AuNP/SPCE) were characterised using Field Emission Scanning Electron Microscopy (FESEM), Energy Dispersive X-ray (EDX), and X-ray Diffraction (XRD) with deposition at -0.8 V and +0.56 V, proving that the gold nanostructures were deposited at the SPCE surface.The deposition at +0.9 V had an insignificant amount of Au on the SPCE surface, similar to bare SPCE.The active sites and reversibility of the gold electrode can be determined by measuring the electrochemical active surface area (ECSA) of electrode and its anodic and cathodic peak current density ratio (Ipa/Ipc), respectively.The ECSA for modified SPCE with different potentials of -0.8 V, +0.56 V, and +0.9 V were 6.873 cm 2 , 0.786 cm 2 , and 0.253 cm 2 , respectively.The Ipa/Ipc ratio of +0.56 V and -0.8 V showed excellent reversibility and transfer rate compared to +0.9 V. Thus, deposition at -0.8 V and +0.56 V was chosen to detect glucose, and the sensitivity and limit of detection (LOD) were calculated.The sensitivity and LOD for these two modified electrodes (-0.8 V and +0.56 V) were 7.53 mA.mM -1 cm -2 and 14.73 mM, as well as 73.38 mA.mM -1 cm -2 and 13.13 mM, respectively.

Malaysian Journal of ChemistryVol. 26(5)
Universiti Teknologi MARA
Openalex Percentile: Top 86%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.