Characterisation of surface morphology of high voltage DC relay contacts under arc erosion

Abstract High voltage DC relays are a crucial component in new energy vehicles. Due to the high failure rate caused by contact sticking (fusion welding), existing technologies can only analyze contact morphology after failure. There is an urgent need to determine the quantitative characterization value of contact surface morphology and the correlation between morphology, failure mechanisms, and working conditions. In this study, an Olympus DSX1000 microscope is used to extract surface topography data, and a quantitative topography characterization method based on a machine vision system is proposed to quantitatively analyze contact surface changes after arc erosion. Grey correlation analysis was applied to explore the relationship between electrical parameters such as voltage, current, and capacitance, and the contact morphology features. The results show that current and capacitance have the greatest influence on contact surface features after arc erosion, while voltage has a relatively smaller influence. This conclusion is consistent with the experimentally observed arc erosion features. Finally, an arc ion sputtering deposition model was developed to analyze the material transfer mode and its influence on the contact failure mechanism. The results provide a scientific basis for the analysis and design improvement of high voltage DC relays.

Authors

Institutions

Publication Details

Journal
Surface Topography Metrology and Properties
Published
2024-09-30
DOI
https://doi.org/10.1088/2051-672x/ad8174
Citations
1
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterisation of surface morphology of high voltage DC relay contacts under arc erosion

Haitao Wang, Zhen Lin, Kai Wu, Wei Li et al.
1 citations
Surface Topography Metrology and Properties
Electrical Contact Performance and Analysis
0.21
article

Characterisation of surface morphology of high voltage DC relay contacts under arc erosion

Haitao Wang, Zhen Lin, Kai Wu, Wei Li, Wenli Jiang, Qinneng Liu, Tao Yang
article en
1 citations

Abstract

Abstract High voltage DC relays are a crucial component in new energy vehicles. Due to the high failure rate caused by contact sticking (fusion welding), existing technologies can only analyze contact morphology after failure. There is an urgent need to determine the quantitative characterization value of contact surface morphology and the correlation between morphology, failure mechanisms, and working conditions. In this study, an Olympus DSX1000 microscope is used to extract surface topography data, and a quantitative topography characterization method based on a machine vision system is proposed to quantitatively analyze contact surface changes after arc erosion. Grey correlation analysis was applied to explore the relationship between electrical parameters such as voltage, current, and capacitance, and the contact morphology features. The results show that current and capacitance have the greatest influence on contact surface features after arc erosion, while voltage has a relatively smaller influence. This conclusion is consistent with the experimentally observed arc erosion features. Finally, an arc ion sputtering deposition model was developed to analyze the material transfer mode and its influence on the contact failure mechanism. The results provide a scientific basis for the analysis and design improvement of high voltage DC relays.

Surface Topography Metrology and PropertiesVol. 12(4)
Hebei University of Technology (CN), Collaborative Innovation Center of Chemical Science and Engineering Tianjin (CN), Institute of Contemporary History (SI)
Natural Science Foundation of Hebei Province
Openalex Percentile: Top 51%
Electrical Contact Performance and Analysis
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characterisation of surface morphology of high voltage DC relay contacts under arc erosion — Haitao Wang, Zhen Lin, et al. · Surface Topography Metrology and Properties (2024) | TGRS Research Map | TGRS