SATURATION OF GAS CONCENTRATION SIGNAL OF THE LASER GAS SENSOR

Nowadays it is possible to determine the type of gas with sufficient accuracy when its concentration is less than fractions using spectroscopic methods (optical, radio engineering, acoustic). Along with this, the value of permissible concentrations of explosive, toxic, harmful to technology and ecology gases is practically important. Known physical experimental studies indicate only a linear dependence of the response of a laser gas sensor at units . The research methods for units are based on the processes of combustion, micro-explosion, structural and phase transformations and are not always applicable in real practical conditions. The work is devoted to the analysis of experimentally obtained fluctuations caused by a laser beam in a gas in a photodiode (signal receiver) due to its influence not only at the atomic level, but also on the scale of clusters of nanoparticle molecules. The gas concentration is estimated by the fluctuation-dissipation ratio. It is shown that the signal correlator is saturated to a constant value when the quantum (laser photon energy) and thermal (nanoparticle temperature) factors are comparable with an increase in the concentration of the target gas. The critical values of the saturation concentration are determined by the equality of these two factors.

Authors

Publication Details

Journal
Eurasian Physical Technical Journal
Published
2024-09-30
DOI
https://doi.org/10.31489/2024no3/71-80
Primary Topic
Laser Design and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SATURATION OF GAS CONCENTRATION SIGNAL OF THE LASER GAS SENSOR

Z. Zh. Zhanabaev
Eurasian Physical Technical Journal
Laser Design and Applications
article

SATURATION OF GAS CONCENTRATION SIGNAL OF THE LASER GAS SENSOR

Z. Zh. Zhanabaev
article en

Abstract

Nowadays it is possible to determine the type of gas with sufficient accuracy when its concentration is less than fractions using spectroscopic methods (optical, radio engineering, acoustic). Along with this, the value of permissible concentrations of explosive, toxic, harmful to technology and ecology gases is practically important. Known physical experimental studies indicate only a linear dependence of the response of a laser gas sensor at units . The research methods for units are based on the processes of combustion, micro-explosion, structural and phase transformations and are not always applicable in real practical conditions. The work is devoted to the analysis of experimentally obtained fluctuations caused by a laser beam in a gas in a photodiode (signal receiver) due to its influence not only at the atomic level, but also on the scale of clusters of nanoparticle molecules. The gas concentration is estimated by the fluctuation-dissipation ratio. It is shown that the signal correlator is saturated to a constant value when the quantum (laser photon energy) and thermal (nanoparticle temperature) factors are comparable with an increase in the concentration of the target gas. The critical values of the saturation concentration are determined by the equality of these two factors.

Eurasian Physical Technical JournalVol. 21(3(49))
Al-Farabi Kazakh National University
Openalex Percentile: Top 86%
Laser Design and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

SATURATION OF GAS CONCENTRATION SIGNAL OF THE LASER GAS SENSOR — Z. Zh. Zhanabaev · Eurasian Physical Technical Journal (2024) | TGRS Research Map | TGRS