Spectrophotometric determination of Salicylamide one of the novel COVID -19 protocols via new design Flow Injection with Merging-Zone Technique

Recently, attention has turned to drugs like salicylamide for treating COVID-19. Several studies have reported simple, fast, and sensitive methods for measuring salicylamide levels. However, potential limitations remain regarding interference from other drugs and accuracy of results. To tackle this issue, researchers combined the standard addition technique with flow injection analysis. As part of this investigation, the reaction involving Fe (III), salicylamide, and 1,10-phenanthroline at a temperature of 55°C was examined using a spectrophotometer set at a wavelength of 528 nm. Thus, the new design was able to show an excellent linearity over the concentration range of (2-30 μg/mL) and (25-300 μg/mL), with correlation coefficients ( ) of 0.9669 and 0.9781, respectively. In addition, physical and chemical variables were optimized to obtain the best results. There was a significant positive correlation between the new design and NIR micro-spectrometers device (handheld) outcomes.

Authors

Institutions

Publication Details

Journal
Iraqi Journal of Science
Published
2024-09-30
DOI
https://doi.org/10.24996/ijs.2024.65.9.4
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectrophotometric determination of Salicylamide one of the novel COVID -19 protocols via new design Flow Injection with Merging-Zone Technique

Shurooq Badri Al-Badri, Yasmeen H. Muhamad
Iraqi Journal of Science
Analytical Methods in Pharmaceuticals
article

Spectrophotometric determination of Salicylamide one of the novel COVID -19 protocols via new design Flow Injection with Merging-Zone Technique

Shurooq Badri Al-Badri, Yasmeen H. Muhamad
article en

Abstract

Recently, attention has turned to drugs like salicylamide for treating COVID-19. Several studies have reported simple, fast, and sensitive methods for measuring salicylamide levels. However, potential limitations remain regarding interference from other drugs and accuracy of results. To tackle this issue, researchers combined the standard addition technique with flow injection analysis. As part of this investigation, the reaction involving Fe (III), salicylamide, and 1,10-phenanthroline at a temperature of 55°C was examined using a spectrophotometer set at a wavelength of 528 nm. Thus, the new design was able to show an excellent linearity over the concentration range of (2-30 μg/mL) and (25-300 μg/mL), with correlation coefficients ( ) of 0.9669 and 0.9781, respectively. In addition, physical and chemical variables were optimized to obtain the best results. There was a significant positive correlation between the new design and NIR micro-spectrometers device (handheld) outcomes.

Iraqi Journal of Science
University of Baghdad (IQ)
Openalex Percentile: Top 85%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.