Design of high-performance electrochemical sensor based on SnS<sub>2</sub> nanoplates and ionic liquid-modified carbon paste electrode for determination of hydrazine in water samples

Designing effective and accurate analytical techniques to determine hydrazine is essential for preserving the environment. Herein, an electrochemical sensor based on a carbon paste electrode (CPE) modified with SnS2 nanoplates (SnS2NPs) and ionic liquid (IL) was presented for determination of hydrazine in water samples. The SnS2NPs were synthesized using the hydrothermal method and characterized through field emission scanning electron microscope, Fourier transform infrared spectrometer and energy dispersive spectroscopy. The use of cyclic voltammetry in electrochemical investigations has shown that incorporating IL and SnS2NPs in an electrochemical sensor significantly improves its efficiency. These results in a considerable increase in the oxidation peak current and a decrease in the oxidation peak potential of hydrazine compared to an unmodified CPE. The method of differential pulse voltammetry was utilized to accurately measure the quantity of hydrazine. The SnS2NPs/ILCPE showed improved sensing capabilities, resulting in a noticeable sensitivity of 0.0747 µA/µM and a low limit of detection of 0.05 µM for a broad linear range of hydrazine concentration from 0.08 µM to 450.0 µM. In addition, the SnS2NPs/ILCPE sensor was successfully utilized to measure the amount of hydrazine present in water samples, with a recovery range of 96.0 to 104.4 %. The relative standard deviation was found to be lower than 3.6 % (n = 5), indicating that the developed sensor is suitable for accurately determining hydrazine in water samples with high sensitivity.

Authors

Institutions

Publication Details

Journal
Journal of Electrochemical Science and Engineering
Published
2024-09-30
DOI
https://doi.org/10.5599/jese.2350
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of high-performance electrochemical sensor based on SnS2 nanoplates and ionic liquid-modified carbon paste electrode for determination of hydrazine in water samples

Afsaneh Haji Alizadeh, Abdulhamid Morshidi Nozar, Samaneh Salemi Najaf Abadi
1 citations
Journal of Electrochemical Science and Engineering
Electrochemical sensors and biosensors
0.21
article

Design of high-performance electrochemical sensor based on SnS2 nanoplates and ionic liquid-modified carbon paste electrode for determination of hydrazine in water samples

Afsaneh Haji Alizadeh, Abdulhamid Morshidi Nozar, Samaneh Salemi Najaf Abadi
article en
1 citations

Abstract

Designing effective and accurate analytical techniques to determine hydrazine is essential for preserving the environment. Herein, an electrochemical sensor based on a carbon paste electrode (CPE) modified with SnS2 nanoplates (SnS2NPs) and ionic liquid (IL) was presented for determination of hydrazine in water samples. The SnS2NPs were synthesized using the hydrothermal method and characterized through field emission scanning electron microscope, Fourier transform infrared spectrometer and energy dispersive spectroscopy. The use of cyclic voltammetry in electrochemical investigations has shown that incorporating IL and SnS2NPs in an electrochemical sensor significantly improves its efficiency. These results in a considerable increase in the oxidation peak current and a decrease in the oxidation peak potential of hydrazine compared to an unmodified CPE. The method of differential pulse voltammetry was utilized to accurately measure the quantity of hydrazine. The SnS2NPs/ILCPE showed improved sensing capabilities, resulting in a noticeable sensitivity of 0.0747 µA/µM and a low limit of detection of 0.05 µM for a broad linear range of hydrazine concentration from 0.08 µM to 450.0 µM. In addition, the SnS2NPs/ILCPE sensor was successfully utilized to measure the amount of hydrazine present in water samples, with a recovery range of 96.0 to 104.4 %. The relative standard deviation was found to be lower than 3.6 % (n = 5), indicating that the developed sensor is suitable for accurately determining hydrazine in water samples with high sensitivity.

Journal of Electrochemical Science and EngineeringVol. 14(5)
Islamic Azad University, Sirjan Branch (IR)
Affordable and clean energy
Openalex Percentile: Top 48%
Electrochemical sensors and biosensors
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.