Deep learning segmentation model for quantification of infarct size in pigs with myocardial ischemia/reperfusion

Infarct size (IS) is the most robust end point for evaluating the success of preclinical studies on cardioprotection. The gold standard for IS quantification in ischemia/reperfusion (I/R) experiments is triphenyl tetrazolium chloride (TTC) staining, typically done manually. This study aimed to determine if automation through deep learning segmentation is a time-saving and valid alternative to standard IS quantification. High-resolution images from TTC-stained, macroscopic heart slices were retrospectively collected from pig experiments (n = 390) with I/R without/with cardioprotection to cover a wide IS range. Existing IS data from pig experiments, quantified using a standard method of manual and subsequent digital labeling of film-scan annotations, were used as reference. To automate the evaluation process with the aim to be more objective and save time, a deep learning pipeline was implemented; the collected images (n = 3869) were pre-processed by cropping and labeled (image annotations). To ensure their usability as training data for a deep learning segmentation model, IS was quantified from image annotations and compared to IS quantified using the existing film-scan annotations. A supervised deep learning segmentation model based on dynamic U-Net architecture was developed and trained. The evaluation of the trained model was performed by fivefold cross-validation (n = 220 experiments) and testing on an independent test set (n = 170 experiments). Performance metrics (Dice similarity coefficient [DSC], pixel accuracy [ACC], average precision [mAP]) were calculated. IS was then quantified from predictions and compared to IS quantified from image annotations (linear regression, Pearson's r; analysis of covariance; Bland-Altman plots). Performance metrics near 1 indicated a strong model performance on cross-validated data (DSC: 0.90, ACC: 0.98, mAP: 0.90) and on the test set data (DSC: 0.89, ACC: 0.98, mAP: 0.93). IS quantified from predictions correlated well with IS quantified from image annotations in all data sets (cross-validation: r = 0.98; test data set: r = 0.95) and analysis of covariance identified no significant differences. The model reduced the IS quantification time per experiment from approximately 90 min to 20 s. The model was further tested on a preliminary test set from experiments in isolated, saline-perfused rat hearts with regional I/R without/with cardioprotection (n = 27). There was also no significant difference in IS between image annotations and predictions, but the performance on the test set data from rat hearts was lower (DSC: 0.66, ACC: 0.91, mAP: 0.65). IS quantification using a deep learning segmentation model is a valid and time-efficient alternative to manual and subsequent digital labeling.

Authors

Institutions

Publication Details

Journal
Basic Research in Cardiology
Published
2024-09-30
DOI
https://doi.org/10.1007/s00395-024-01081-x
Citations
1
Primary Topic
Cardiac Ischemia and Reperfusion
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep learning segmentation model for quantification of infarct size in pigs with myocardial ischemia/reperfusion

Helmut Raphael Lieder, Andreas Skyschally, Felix Braczko, Petra Kleinbongard et al.
1 citations
Basic Research in Cardiology
Cardiac Ischemia and Reperfusion
0.42
article

Deep learning segmentation model for quantification of infarct size in pigs with myocardial ischemia/reperfusion

Helmut Raphael Lieder, Andreas Skyschally, Felix Braczko, Petra Kleinbongard, Jakob Nikolas Kather, Gerd Heusch
article en
1 citations

Abstract

Infarct size (IS) is the most robust end point for evaluating the success of preclinical studies on cardioprotection. The gold standard for IS quantification in ischemia/reperfusion (I/R) experiments is triphenyl tetrazolium chloride (TTC) staining, typically done manually. This study aimed to determine if automation through deep learning segmentation is a time-saving and valid alternative to standard IS quantification. High-resolution images from TTC-stained, macroscopic heart slices were retrospectively collected from pig experiments (n = 390) with I/R without/with cardioprotection to cover a wide IS range. Existing IS data from pig experiments, quantified using a standard method of manual and subsequent digital labeling of film-scan annotations, were used as reference. To automate the evaluation process with the aim to be more objective and save time, a deep learning pipeline was implemented; the collected images (n = 3869) were pre-processed by cropping and labeled (image annotations). To ensure their usability as training data for a deep learning segmentation model, IS was quantified from image annotations and compared to IS quantified using the existing film-scan annotations. A supervised deep learning segmentation model based on dynamic U-Net architecture was developed and trained. The evaluation of the trained model was performed by fivefold cross-validation (n = 220 experiments) and testing on an independent test set (n = 170 experiments). Performance metrics (Dice similarity coefficient [DSC], pixel accuracy [ACC], average precision [mAP]) were calculated. IS was then quantified from predictions and compared to IS quantified from image annotations (linear regression, Pearson's r; analysis of covariance; Bland-Altman plots). Performance metrics near 1 indicated a strong model performance on cross-validated data (DSC: 0.90, ACC: 0.98, mAP: 0.90) and on the test set data (DSC: 0.89, ACC: 0.98, mAP: 0.93). IS quantified from predictions correlated well with IS quantified from image annotations in all data sets (cross-validation: r = 0.98; test data set: r = 0.95) and analysis of covariance identified no significant differences. The model reduced the IS quantification time per experiment from approximately 90 min to 20 s. The model was further tested on a preliminary test set from experiments in isolated, saline-perfused rat hearts with regional I/R without/with cardioprotection (n = 27). There was also no significant difference in IS between image annotations and predictions, but the performance on the test set data from rat hearts was lower (DSC: 0.66, ACC: 0.91, mAP: 0.65). IS quantification using a deep learning segmentation model is a valid and time-efficient alternative to manual and subsequent digital labeling.

Basic Research in CardiologyVol. 119(6)
West German Heart and Vascular Center Essen (DE), University Hospital Carl Gustav Carus (DE), RWTH Aachen University (DE)
Universitätsklinikum Essen, European Commission, Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 34%
Cardiac Ischemia and Reperfusion
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.