3D printed hernia mesh implant: a conformability study

Aim: This study aims to explore the sensing capabilities of polyvinylidene fluoride-hydroxyapatite-chitosan (PVDF-HAP-CS) composite-based hernia mesh implants (of conformal/planar design), followed by in-vitro analysis for better understanding of the bio-stability in the patient’s body. Methods: For analyzing the sensing capabilities, a microstrip patch antenna (MPA)-based implantable sensor [with 17-4 precipitate hardened (PH) stainless steel (SS) (bio-compatible) and Cu alloy (non-biocompatible) materials as conducting plane/patch with PVDF-HAP-CS as dielectric material] has been considered separately in this study. Primarily, in this study, the 3D models of the hernia mesh implant have been designed in the high-frequency structure simulator (HFSS) software, and the sensing behaviour of the same has been recorded. Results: The HFSS results represent that for the 17-4PH SS-based sensor, resonant frequency (fr) decreases from 2.3953 to 2.3800 GHz, whereas the gain increases from 0.54 to 4.02 dB with a SAR value of 1.077 W/kg. The fr for Cu alloy increases up to 30° conformal angle and, after that, starts decreasing, whereas the gain reaches 3.24 dB with a SAR value of 1.238 W/kg. The in-vitro study highlights that both materials (17-4PH SS and Cu alloy) possess a low corrosion rate. Conclusions: The simulation-based comparison of the biosensors with conducting elements 17-4PH SS and Cu alloy for different conformal angles indicates that the 17-4PH SS shows promising results over Cu in terms of higher gain (up to 4.02 dB) and low SAR value (1.077 W/kg) with the fr lying in the industry scientific and medical (ISM) band and therefore may be used for implantable sensor applications and possesses the capability to be used as 3D-printed hernia mesh implant. The in-vitro results with the low corrosion rate ≈ of 5.1 × 10–8 mm/year, 17-4PH SS may be a suitable material for the fabrication of hernia mesh implant.

Authors

Institutions

Publication Details

Journal
Exploration of BioMat-X
Published
2024-09-30
DOI
https://doi.org/10.37349/ebmx.2024.00019
Primary Topic
Anatomy and Medical Technology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D printed hernia mesh implant: a conformability study

J. Paulo Davim, Abhishek Barwar, Rupinder Singh, Prateek Kala
Exploration of BioMat-X
Anatomy and Medical Technology
article

3D printed hernia mesh implant: a conformability study

J. Paulo Davim, Abhishek Barwar, Rupinder Singh, Prateek Kala
article en

Abstract

Aim: This study aims to explore the sensing capabilities of polyvinylidene fluoride-hydroxyapatite-chitosan (PVDF-HAP-CS) composite-based hernia mesh implants (of conformal/planar design), followed by in-vitro analysis for better understanding of the bio-stability in the patient’s body. Methods: For analyzing the sensing capabilities, a microstrip patch antenna (MPA)-based implantable sensor [with 17-4 precipitate hardened (PH) stainless steel (SS) (bio-compatible) and Cu alloy (non-biocompatible) materials as conducting plane/patch with PVDF-HAP-CS as dielectric material] has been considered separately in this study. Primarily, in this study, the 3D models of the hernia mesh implant have been designed in the high-frequency structure simulator (HFSS) software, and the sensing behaviour of the same has been recorded. Results: The HFSS results represent that for the 17-4PH SS-based sensor, resonant frequency (fr) decreases from 2.3953 to 2.3800 GHz, whereas the gain increases from 0.54 to 4.02 dB with a SAR value of 1.077 W/kg. The fr for Cu alloy increases up to 30° conformal angle and, after that, starts decreasing, whereas the gain reaches 3.24 dB with a SAR value of 1.238 W/kg. The in-vitro study highlights that both materials (17-4PH SS and Cu alloy) possess a low corrosion rate. Conclusions: The simulation-based comparison of the biosensors with conducting elements 17-4PH SS and Cu alloy for different conformal angles indicates that the 17-4PH SS shows promising results over Cu in terms of higher gain (up to 4.02 dB) and low SAR value (1.077 W/kg) with the fr lying in the industry scientific and medical (ISM) band and therefore may be used for implantable sensor applications and possesses the capability to be used as 3D-printed hernia mesh implant. The in-vitro results with the low corrosion rate ≈ of 5.1 × 10–8 mm/year, 17-4PH SS may be a suitable material for the fabrication of hernia mesh implant.

Exploration of BioMat-X
National Institute of Technical Teachers Training and Research, Chandigarh (IN), University of Aveiro (PT), Birla Institute of Technology and Science, Pilani (IN)
Guru Angad Dev Veterinary and Animal Sciences University
Openalex Percentile: Top 85%
Anatomy and Medical Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.