Development and validation of RP-HPLC method with UV-DAD detection for simultaneous determination of acesulfame K, sodium saccharin and aspartame in beverages

Abstract Artificial sweeteners are low-calorie substances used as food additives with aim to impart a sweet taste to beverages without adding significant calories. Due to the regulatory compliance regarding the type and the amount of artificial sweetener, and due to the large consumption of beverages and the effects of artificial sweeteners on human health, their identification and quantification is of a great importance. In this research simultaneous determination of acesulfame K (ACE-K), sodium saccharin (Na-SAC) and aspartame (ASP) as the most commonly used sweeteners in beverages was performed with a reversed – phase high performance liquid chromatography (RP – HPLC) with diode array detection (DAD). The best separation of the analytes was achieved on a Poroshell 120 EC-C18 (3.0 × 50 mm, 2.7 µm) column and isocratic elution with a mobile phase consisted of acetonitrile and diluted phosphoric acid (pH = 3.8) with 7/93 volume ratio ( V/V ), and flow rate of 1 mL min −1 . The chromatographic process was followed at 195, 220 and 230 nm, under constant column temperature (25 °C). Under these chromatographic conditions, the total time of analysis was less than 5 min. The developed method was validated for linearity, precision, accuracy, limit of detection (LOD) and limit of quantification (LOQ). The LOD under established chromatographic conditions was 0.03, 0.07 and 0.17 mg L −1 for Na-SAC, ACE-K and ASP, respectively. The amount of artificial sweeteners in analyzed samples ranged from 30.32 to 148.37 mg L −1 for ACE-K, from 16.10 to 93.05 for Na-SAC, and from 6.06 to 512.72 for ASP. The validated method was successfully applied for determination of analytes in different commercially available beverages.

Authors

Institutions

Publication Details

Journal
Acta Chromatographica
Published
2024-09-30
DOI
https://doi.org/10.1556/1326.2024.01239
Citations
3
Primary Topic
Biochemical Analysis and Sensing Techniques
Type
article
Field-Weighted Citation Impact
0.93
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of RP-HPLC method with UV-DAD detection for simultaneous determination of acesulfame K, sodium saccharin and aspartame in beverages

Mirjana Jankulovska, Lenche Velkoska-Markovska, Teodora Josimovska
3 citations
Acta Chromatographica
Biochemical Analysis and Sensing Techniques
0.93
article

Development and validation of RP-HPLC method with UV-DAD detection for simultaneous determination of acesulfame K, sodium saccharin and aspartame in beverages

Mirjana Jankulovska, Lenche Velkoska-Markovska, Teodora Josimovska
article en
3 citations

Abstract

Abstract Artificial sweeteners are low-calorie substances used as food additives with aim to impart a sweet taste to beverages without adding significant calories. Due to the regulatory compliance regarding the type and the amount of artificial sweetener, and due to the large consumption of beverages and the effects of artificial sweeteners on human health, their identification and quantification is of a great importance. In this research simultaneous determination of acesulfame K (ACE-K), sodium saccharin (Na-SAC) and aspartame (ASP) as the most commonly used sweeteners in beverages was performed with a reversed – phase high performance liquid chromatography (RP – HPLC) with diode array detection (DAD). The best separation of the analytes was achieved on a Poroshell 120 EC-C18 (3.0 × 50 mm, 2.7 µm) column and isocratic elution with a mobile phase consisted of acetonitrile and diluted phosphoric acid (pH = 3.8) with 7/93 volume ratio ( V/V ), and flow rate of 1 mL min −1 . The chromatographic process was followed at 195, 220 and 230 nm, under constant column temperature (25 °C). Under these chromatographic conditions, the total time of analysis was less than 5 min. The developed method was validated for linearity, precision, accuracy, limit of detection (LOD) and limit of quantification (LOQ). The LOD under established chromatographic conditions was 0.03, 0.07 and 0.17 mg L −1 for Na-SAC, ACE-K and ASP, respectively. The amount of artificial sweeteners in analyzed samples ranged from 30.32 to 148.37 mg L −1 for ACE-K, from 16.10 to 93.05 for Na-SAC, and from 6.06 to 512.72 for ASP. The validated method was successfully applied for determination of analytes in different commercially available beverages.

Acta ChromatographicaVol. 37(3)
Ss. Cyril and Methodius University in Skopje (MK)
Openalex Percentile: Top 27%
Biochemical Analysis and Sensing Techniques
0.93
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.