Ionic Liquid-Based Hybrid Gel Microcolumns for Enhanced Narcotic Detection in Portable Micro-Gas Chromatography

As the societal issue of increasing global illicit drug usage emerges, there is a growing demand for more portable and versatile drug detectors. Traditional drug analysis techniques such as gas chromatography (GC), liquid chromatography (LC), and Fourier transform infrared spectroscopy (FTIR) face significant challenges in adapting to diverse real-world applications due to their size, cost, and power requirements. While advancements have been made in the development of on-site drug detection methods such as fluorescence, stereoresonance energy transfer (FRET), colorimetric, electrochemical sensing, and lateral flow assays (LFAs), their reliance on specific reactive materials poses limitations in effectively detecting a wide range of narcotics. Therefore, this study proposes the development of specialized microcolumns with optimized stationary phases for next-generation portable microfabricated GC-based narcotic detectors. The stationary phase consists of a hybrid gel incorporating the ionic liquid, 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM][BF<sub>4</sub>]) and OV-1. The stationary phase not only enhances interactions between drug analytes but also demonstrates improved separation characteristics among various narcotic substances. Additionally, the principles of the separation results were validated through density functional theory (DFT) analysis, and the effective separation of over seven types of narcotics was demonstrated through temperature optimization. This research lays the groundwork for the advancement of next-generation portable drug analyzers, offering significant potential in the field.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2024-09-30
DOI
https://doi.org/10.1021/acsami.4c10094
Citations
7
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
1.29

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ionic Liquid-Based Hybrid Gel Microcolumns for Enhanced Narcotic Detection in Portable Micro-Gas Chromatography

Jung Hwan Seo, Sung Myung, So Young Kim, Yong‐Sung Kim et al.
7 citations
ACS Applied Materials & Interfaces
Advanced Chemical Sensor Technologies
1.29
article

Ionic Liquid-Based Hybrid Gel Microcolumns for Enhanced Narcotic Detection in Portable Micro-Gas Chromatography

Jung Hwan Seo, Sung Myung, So Young Kim, Yong‐Sung Kim, Sung-Kuk Bae
article en
7 citations

Abstract

As the societal issue of increasing global illicit drug usage emerges, there is a growing demand for more portable and versatile drug detectors. Traditional drug analysis techniques such as gas chromatography (GC), liquid chromatography (LC), and Fourier transform infrared spectroscopy (FTIR) face significant challenges in adapting to diverse real-world applications due to their size, cost, and power requirements. While advancements have been made in the development of on-site drug detection methods such as fluorescence, stereoresonance energy transfer (FRET), colorimetric, electrochemical sensing, and lateral flow assays (LFAs), their reliance on specific reactive materials poses limitations in effectively detecting a wide range of narcotics. Therefore, this study proposes the development of specialized microcolumns with optimized stationary phases for next-generation portable microfabricated GC-based narcotic detectors. The stationary phase consists of a hybrid gel incorporating the ionic liquid, 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM][BF<sub>4</sub>]) and OV-1. The stationary phase not only enhances interactions between drug analytes but also demonstrates improved separation characteristics among various narcotic substances. Additionally, the principles of the separation results were validated through density functional theory (DFT) analysis, and the effective separation of over seven types of narcotics was demonstrated through temperature optimization. This research lays the groundwork for the advancement of next-generation portable drug analyzers, offering significant potential in the field.

ACS Applied Materials & InterfacesVol. 16(48)
Korea Research Institute of Standards and Science (KR), Korea Research Institute of Chemical Technology (KR), Hongik University (KR)
National Research Foundation of Korea
Openalex Percentile: Top 21%
Advanced Chemical Sensor Technologies
1.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.