In Situ Assembly of Dual Mobility Liners in Isolated Cup Revision in Hip Arthroplasty: A Technical Note

Objective: Isolated cup revisions to a dual mobility system through the minimally invasive direct anterior approach represent a major challenge in revision hip arthroplasty. Materials and Methods: We present 2 cases of isolated cup revision to a dual mobility system due to aseptic loosening, in which the dual mobility liners were assembled in situ. In the first case, a well-fixed cemented monobloc stem did not require revision; in the second, the collared prosthetic head could not be removed from the well-fixed stem. Results: In situ assembly of the polyethylene liner to the prosthetic head was performed using the standard press, designed for back-table assembly. Conclusion: In situ assembly of dual mobility liners is technically simple using standard instruments and can be performed through a direct anterior approach.

Authors

Institutions

Publication Details

Journal
Techniques in Orthopaedics
Published
2024-09-30
DOI
https://doi.org/10.1097/bto.0000000000000679
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Situ Assembly of Dual Mobility Liners in Isolated Cup Revision in Hip Arthroplasty: A Technical Note

Michael Leunig, Louisa Bell, Hannes A. Rüdiger, Tobias Bühler
Techniques in Orthopaedics
Orthopaedic implants and arthroplasty
article

In Situ Assembly of Dual Mobility Liners in Isolated Cup Revision in Hip Arthroplasty: A Technical Note

Michael Leunig, Louisa Bell, Hannes A. Rüdiger, Tobias Bühler
article en

Abstract

Objective: Isolated cup revisions to a dual mobility system through the minimally invasive direct anterior approach represent a major challenge in revision hip arthroplasty. Materials and Methods: We present 2 cases of isolated cup revision to a dual mobility system due to aseptic loosening, in which the dual mobility liners were assembled in situ. In the first case, a well-fixed cemented monobloc stem did not require revision; in the second, the collared prosthetic head could not be removed from the well-fixed stem. Results: In situ assembly of the polyethylene liner to the prosthetic head was performed using the standard press, designed for back-table assembly. Conclusion: In situ assembly of dual mobility liners is technically simple using standard instruments and can be performed through a direct anterior approach.

Techniques in OrthopaedicsVol. 40(1)
Schulthess-Klinik (CH), Kantonsspital Baden (CH)
Openalex Percentile: Top 69%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.