Real-Time Monitoring of Oxygen-Consumption Rate in Mouse Liver Slices Incubated in Organ-on-a-Chip Devices

We developed an organ-on-a-chip (OOC) based on precision-cut liver slices to assess liver function in real-time, both in health and disease, in a controlled and noninvasive manner. We achieved this by integrating fiber-optic-based oxygen sensors before and after the microchamber in which a liver slice was incubated under flow, to measure oxygen concentrations in the medium in real time. We first demonstrated that the basal oxygen consumption rate (OCR) of liver slices is a reliable indicator of liver slice viability. By monitoring basal OCR (2.9-5.7 pmol O<sub>2</sub>/min/μg protein) in incubation medium, we found that it correlated well to cellular adenosine triphosphate (ATP) content (3.0-7.9 pmol/μg protein) (<i>r</i> = 0.82, <i>p</i> < 0.0001). Second, we induced a diseased state in liver slices by targeting the mitochondria, as they play a critical role in liver function and disease. We exposed the liver slices to succinate in abundance (40 mM) for short periods (1 h) to rapidly boost mitochondrial OCR. Two successive treatments of succinate increased the OCR of liver slices by 1.5 pmol/min/μg each time. However, between treatments, the liver slice OCR did not return to its basal OCR, instead decreasing drastically by 60-70%, suggesting succinate toxicity. We confirmed this with ATP analysis (1.0 pmol/μg protein) and hematoxylin and eosin staining, which showed tissue necrosis and apoptosis. Our system could be an advantageous model for future studies assessing liver (patho)physiology in response to potentially toxic drugs or lifestyle-related liver diseases.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-09-30
DOI
https://doi.org/10.1021/acs.analchem.4c00355
Citations
9
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
1.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Monitoring of Oxygen-Consumption Rate in Mouse Liver Slices Incubated in Organ-on-a-Chip Devices

Peter Olinga, Konstanze Gier, Jean-Paul S. H. Mulder, Elisabeth Verpoorte et al.
9 citations
Analytical Chemistry
3D Printing in Biomedical Research
1.66
article

Real-Time Monitoring of Oxygen-Consumption Rate in Mouse Liver Slices Incubated in Organ-on-a-Chip Devices

Peter Olinga, Konstanze Gier, Jean-Paul S. H. Mulder, Elisabeth Verpoorte, Ruby E. H. Karsten, Maciej Grajewski
article en
9 citations

Abstract

We developed an organ-on-a-chip (OOC) based on precision-cut liver slices to assess liver function in real-time, both in health and disease, in a controlled and noninvasive manner. We achieved this by integrating fiber-optic-based oxygen sensors before and after the microchamber in which a liver slice was incubated under flow, to measure oxygen concentrations in the medium in real time. We first demonstrated that the basal oxygen consumption rate (OCR) of liver slices is a reliable indicator of liver slice viability. By monitoring basal OCR (2.9-5.7 pmol O<sub>2</sub>/min/μg protein) in incubation medium, we found that it correlated well to cellular adenosine triphosphate (ATP) content (3.0-7.9 pmol/μg protein) (<i>r</i> = 0.82, <i>p</i> < 0.0001). Second, we induced a diseased state in liver slices by targeting the mitochondria, as they play a critical role in liver function and disease. We exposed the liver slices to succinate in abundance (40 mM) for short periods (1 h) to rapidly boost mitochondrial OCR. Two successive treatments of succinate increased the OCR of liver slices by 1.5 pmol/min/μg each time. However, between treatments, the liver slice OCR did not return to its basal OCR, instead decreasing drastically by 60-70%, suggesting succinate toxicity. We confirmed this with ATP analysis (1.0 pmol/μg protein) and hematoxylin and eosin staining, which showed tissue necrosis and apoptosis. Our system could be an advantageous model for future studies assessing liver (patho)physiology in response to potentially toxic drugs or lifestyle-related liver diseases.

Analytical ChemistryVol. 96(40)
University of Groningen (NL)
Rijksuniversiteit Groningen, Horizon 2020 Framework Programme
Openalex Percentile: Top 17%
3D Printing in Biomedical Research
1.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.