Jacketed telemetry in rats: a novel non-invasive method for cardiorespiratory phenotyping during treadmill exercise

The development of alternative methods for monitoring cardiorespiratory function without restraint or surgical implantation is attracting growing interest for both ethical and scientific reasons. For this purpose, a new non-invasive jacketed telemetry tool consisting in a radio device maintained in a jacket worn by the animal was previously developed to improve cardiorespiratory monitoring. It allows simultaneous monitoring of cardiac activity by surface electrocardiagram, respiratory function by respiratory inductive plethysmography, and locomotor activity by accelerometry. However, this tool has only been validated under conditions of low/intermediate activity levels or in anesthetized animals. This study aimed to evaluate the feasibility of using this system in the challenging conditions of an exertion protocol. Male Wistar rats (<i>n</i> = 10, 8-9 weeks old) were subjected to an incremental treadmill exercise protocol including speed levels from 5 to 40 cm s<sup>-1</sup> separated by 30-s breaks. Heart rate (HR) and minute ventilation (assessed by minute volume; MV) were continuously monitored. At the end of each running level and during the 30-s breaks, HR and MV showed a significant increase compared to resting values. They returned to the baseline within 60 min of post-exercise recovery. Overall, our results demonstrated (i) the ability of the animal to run while wearing the device and (ii) the ability of the device to reliably monitor cardiorespiratory adaptation to treadmill exercise despite significant mechanical disturbances. In conclusion, this study highlights the possibility of non-invasively monitoring cardiorespiratory functional variables that were previously unattainable under conditions of high activity in freely moving animals.

Authors

Institutions

Publication Details

Journal
Laboratory Animals
Published
2024-09-30
DOI
https://doi.org/10.1177/00236772241259857
Citations
2
Primary Topic
Cardiovascular and exercise physiology
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Jacketed telemetry in rats: a novel non-invasive method for cardiorespiratory phenotyping during treadmill exercise

François R. Boucher, Stéphane Tanguy, Charles Eynard, Timothé Flenet et al.
2 citations
Laboratory Animals
Cardiovascular and exercise physiology
1.43
article

Jacketed telemetry in rats: a novel non-invasive method for cardiorespiratory phenotyping during treadmill exercise

François R. Boucher, Stéphane Tanguy, Charles Eynard, Timothé Flenet, Agathe Cambier, Leandro Fontana-Pires, Julie Fontecave-Jalon, Pierre-Yves Guméry
article en
2 citations

Abstract

The development of alternative methods for monitoring cardiorespiratory function without restraint or surgical implantation is attracting growing interest for both ethical and scientific reasons. For this purpose, a new non-invasive jacketed telemetry tool consisting in a radio device maintained in a jacket worn by the animal was previously developed to improve cardiorespiratory monitoring. It allows simultaneous monitoring of cardiac activity by surface electrocardiagram, respiratory function by respiratory inductive plethysmography, and locomotor activity by accelerometry. However, this tool has only been validated under conditions of low/intermediate activity levels or in anesthetized animals. This study aimed to evaluate the feasibility of using this system in the challenging conditions of an exertion protocol. Male Wistar rats (<i>n</i> = 10, 8-9 weeks old) were subjected to an incremental treadmill exercise protocol including speed levels from 5 to 40 cm s<sup>-1</sup> separated by 30-s breaks. Heart rate (HR) and minute ventilation (assessed by minute volume; MV) were continuously monitored. At the end of each running level and during the 30-s breaks, HR and MV showed a significant increase compared to resting values. They returned to the baseline within 60 min of post-exercise recovery. Overall, our results demonstrated (i) the ability of the animal to run while wearing the device and (ii) the ability of the device to reliably monitor cardiorespiratory adaptation to treadmill exercise despite significant mechanical disturbances. In conclusion, this study highlights the possibility of non-invasively monitoring cardiorespiratory functional variables that were previously unattainable under conditions of high activity in freely moving animals.

Laboratory AnimalsVol. 59(2)
Institut polytechnique de Grenoble (FR), Centre National de la Recherche Scientifique (FR), VetAgro Sup (FR), Sol Agro et hydrosystème Spatialisation (FR), Université Grenoble Alpes (FR)
Good health and well-being
Openalex Percentile: Top 16%
Cardiovascular and exercise physiology
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.