Non-Invasive Ventilation with Neurally Adjusted Ventilatory Assist (NAVA) Improves Extubation Outcomes in Extremely Low-Birth-Weight Infants

<b>Objective:</b> This study investigates the effectiveness of extubation from conventional mechanical ventilation using an endotracheal tube (MVET) compared to synchronized non-invasive positive-pressure ventilation (sNIPPV) using neurally adjusted ventilatory assist (NAVA) and conventional non-invasive positive-pressure ventilation (NIPPV) in extremely low-birth-weight (ELBW) infants. <b>Methods:</b> An institutional review board (IRB) approved this study (#12175) to conduct a single-center randomized control trial including 60 ELBW infants assigned in a one-to-one computer-generated scheme to either sNIPPV using NAVA or NIPPV. The primary outcome involved the need for reintubation, and the secondary outcome involved the assessment of moderate/severe BPD, defined as an oxygen requirement at 36 weeks, as in #NCT03613987 (clinicaltrials.gov). <b>Results:</b> There were 60 ELBW infants enrolled and randomized. The overall gestational age was 26 (1.5) weeks, and the birth weight was 773 (157) g [mean (SD)]. There were no statistically significant differences between the NAVA and NIPPV patient characteristics. There was a 41% extubation failure rate in the NIPPV group and 35% in the NAVA group (<i>p</i> = NS). The NAVA group had less moderate and severe BPD (<i>p</i> = 0.03), a shorter oxygen therapy duration (<i>p</i> = 0.002), a decreased length of stay (<i>p</i> = 0.03), and less need for home oxygen (0, 43%; <i>p</i> = 0.0004). <b>Conclusions:</b> This study found similar extubation failure rates among ELBW infants as in prior studies. However, the NAVA group had lower rates of moderate/severe BPD and need for oxygen at discharge, as well as shorter oxygen therapy duration and length of stay. The use of NAVA may be a reasonable alternative mode of non-invasive ventilation in the ELBW population.

Authors

Institutions

Publication Details

Journal
Children
Published
2024-09-28
DOI
https://doi.org/10.3390/children11101184
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Invasive Ventilation with Neurally Adjusted Ventilatory Assist (NAVA) Improves Extubation Outcomes in Extremely Low-Birth-Weight Infants

Lance A. Parton, Gad Alpan, Shaili Amatya, Kevin Louie
Children
Neonatal Respiratory Health Research
article

Non-Invasive Ventilation with Neurally Adjusted Ventilatory Assist (NAVA) Improves Extubation Outcomes in Extremely Low-Birth-Weight Infants

Lance A. Parton, Gad Alpan, Shaili Amatya, Kevin Louie
article en

Abstract

<b>Objective:</b> This study investigates the effectiveness of extubation from conventional mechanical ventilation using an endotracheal tube (MVET) compared to synchronized non-invasive positive-pressure ventilation (sNIPPV) using neurally adjusted ventilatory assist (NAVA) and conventional non-invasive positive-pressure ventilation (NIPPV) in extremely low-birth-weight (ELBW) infants. <b>Methods:</b> An institutional review board (IRB) approved this study (#12175) to conduct a single-center randomized control trial including 60 ELBW infants assigned in a one-to-one computer-generated scheme to either sNIPPV using NAVA or NIPPV. The primary outcome involved the need for reintubation, and the secondary outcome involved the assessment of moderate/severe BPD, defined as an oxygen requirement at 36 weeks, as in #NCT03613987 (clinicaltrials.gov). <b>Results:</b> There were 60 ELBW infants enrolled and randomized. The overall gestational age was 26 (1.5) weeks, and the birth weight was 773 (157) g [mean (SD)]. There were no statistically significant differences between the NAVA and NIPPV patient characteristics. There was a 41% extubation failure rate in the NIPPV group and 35% in the NAVA group (<i>p</i> = NS). The NAVA group had less moderate and severe BPD (<i>p</i> = 0.03), a shorter oxygen therapy duration (<i>p</i> = 0.002), a decreased length of stay (<i>p</i> = 0.03), and less need for home oxygen (0, 43%; <i>p</i> = 0.0004). <b>Conclusions:</b> This study found similar extubation failure rates among ELBW infants as in prior studies. However, the NAVA group had lower rates of moderate/severe BPD and need for oxygen at discharge, as well as shorter oxygen therapy duration and length of stay. The use of NAVA may be a reasonable alternative mode of non-invasive ventilation in the ELBW population.

ChildrenVol. 11(10)
Westchester Medical Center (US), New York Medical College (US), Maria Fareri Children's Hospital (US), Penn State Milton S. Hershey Medical Center (US), Vanderbilt University Medical Center (US)
Openalex Percentile: Top 69%
Neonatal Respiratory Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.