Fault Diagnosis of Pumped Storage Units—A Novel Data-Model Hybrid-Driven Strategy

Pumped storage units serve as a crucial support for power systems to adapt to large-scale and high-proportion renewable energy sources by providing a stable and flexible energy supply. However, due to the coupling effects of electric power load demands and the complex multi-source factors within the water–mechanical–electrical system, the interrelationship between unit parameters becomes more intricate, posing significant threats to the operational reliability and health status of the units. The complexity of fault diagnosis is further aggravated by the intricate and varied nature of fault characteristics, as well as the challenges in signal extraction under conditions of strong electromagnetic interference and high noise levels. To address these issues, this paper proposes a novel data-model hybrid-driven strategy that analyzes vibration signals to achieve rapid and accurate fault diagnosis of the units. Firstly, the spectral kurtosis theory is employed to enhance the traditional empirical mode decomposition, achieving optimal decomposition and noise reduction effects for vibration signals. Secondly, the intrinsic mode functions (IMFs) obtained from the decomposition are reconstructed, and the entropy values of effective IMFs are calculated as fault feature vectors. Subsequently, the CNN-LSTM model is utilized for fault diagnosis. The effectiveness and feasibility of the proposed method are verified through actual operational data from pumped storage units in a specific region. Through analysis, the fault diagnosis accuracy of the method proposed in this paper can be maintained above 95%, demonstrating robustness in complex engineering environments and effectively ensuring the safe and stable operation of pumped storage units.

Authors

Institutions

Publication Details

Journal
Processes
Published
2024-09-30
DOI
https://doi.org/10.3390/pr12102127
Citations
3
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.98
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Diagnosis of Pumped Storage Units—A Novel Data-Model Hybrid-Driven Strategy

Chuanqiang Che, Bingjie Dou, Zhiqiang He, Haonan Guo et al.
3 citations
Processes
Fault Detection and Control Systems
0.98
article

Fault Diagnosis of Pumped Storage Units—A Novel Data-Model Hybrid-Driven Strategy

Chuanqiang Che, Bingjie Dou, Zhiqiang He, Haonan Guo, Ruida Ma, Xuan Liu, Jie Bai, Hongbo Zou, Lixin Wang, Fucai Xie
article en
3 citations

Abstract

Pumped storage units serve as a crucial support for power systems to adapt to large-scale and high-proportion renewable energy sources by providing a stable and flexible energy supply. However, due to the coupling effects of electric power load demands and the complex multi-source factors within the water–mechanical–electrical system, the interrelationship between unit parameters becomes more intricate, posing significant threats to the operational reliability and health status of the units. The complexity of fault diagnosis is further aggravated by the intricate and varied nature of fault characteristics, as well as the challenges in signal extraction under conditions of strong electromagnetic interference and high noise levels. To address these issues, this paper proposes a novel data-model hybrid-driven strategy that analyzes vibration signals to achieve rapid and accurate fault diagnosis of the units. Firstly, the spectral kurtosis theory is employed to enhance the traditional empirical mode decomposition, achieving optimal decomposition and noise reduction effects for vibration signals. Secondly, the intrinsic mode functions (IMFs) obtained from the decomposition are reconstructed, and the entropy values of effective IMFs are calculated as fault feature vectors. Subsequently, the CNN-LSTM model is utilized for fault diagnosis. The effectiveness and feasibility of the proposed method are verified through actual operational data from pumped storage units in a specific region. Through analysis, the fault diagnosis accuracy of the method proposed in this paper can be maintained above 95%, demonstrating robustness in complex engineering environments and effectively ensuring the safe and stable operation of pumped storage units.

ProcessesVol. 12(10)
China Three Gorges University (CN), Inner Mongolia Electric Power (China) (CN)
Openalex Percentile: Top 23%
Fault Detection and Control Systems
0.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.