AN ANALYSIS ON THE USE OF MODIFIED EXPANDED PERLITE AND PUMICE IN INORGANIC BONDED FIBROUS COMPOSITE BOARDS

It is often stated that there is an energy efficiency difference between optimum energy use and actual energy use in the world. In the construction industry, various building materials are produced and used to optimize energy efficiency in buildings. Among these building materials, inorganic bonded fibrous composite boards, whose energy efficiency criteria have begun to be improved, are widely used both in Türkiye and in the world. This article presents an experimental analysis of the utilization of modified expanded perlite and pumice as key constituents in the development of inorganic bonded fibrous composite boards. The study investigates the influence of these modified porous materials on the physical, mechanical, and thermal properties of the composite boards. For this purpose; composite mortars were produced using micronized quartz sand, a hybrid fiber consisting of cellulose and glass fiber, modified expanded perlite (MEP) with stearic acid (1, 2, 3, 4, 5, 6, 7, 8, 9 wt.%) and modified pumice (MPU) with stearic acid (1, 2, 3, 4, 5, 6, 7, 8, 9 wt.%). In order to make a comparison, a control mortar that did not contain modified expanded perlite and modified pumice was produced. Through a series of experiments, it is concluded that the density values of all other mixture designs with MEP and MPU aggregate additives under equivalent conditions are lower than the control sample. The water absorption values of the samples always remained below the control sample, and with the increase in the MPU ratio and decrease in the MEP ratio, the water absorption values of the samples also decreased. The average modulus of rupture (MOR) value of control sample in the analysis made after 14 days of curing under ambient conditions is 3.73 MPa. The highest MOR value of the test samples is 3.51 MPa, which is the mixture using the highest MPU. The thermal conductivity value of the control mixture is 0.352 W/mK. The thermal conductivity value of test mixtures with MEP and MPU aggregates varies between 0.175 W/mK and 0.287 W/mK.

Authors

Institutions

Publication Details

Journal
Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering
Published
2024-09-28
DOI
https://doi.org/10.18038/estubtda.1447175
Primary Topic
Natural Fiber Reinforced Composites
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AN ANALYSIS ON THE USE OF MODIFIED EXPANDED PERLITE AND PUMICE IN INORGANIC BONDED FIBROUS COMPOSITE BOARDS

Şevket Onur KALKAN, Lütfullah Gündüz
Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering
Natural Fiber Reinforced Composites
article

AN ANALYSIS ON THE USE OF MODIFIED EXPANDED PERLITE AND PUMICE IN INORGANIC BONDED FIBROUS COMPOSITE BOARDS

Şevket Onur KALKAN, Lütfullah Gündüz
article en

Abstract

It is often stated that there is an energy efficiency difference between optimum energy use and actual energy use in the world. In the construction industry, various building materials are produced and used to optimize energy efficiency in buildings. Among these building materials, inorganic bonded fibrous composite boards, whose energy efficiency criteria have begun to be improved, are widely used both in Türkiye and in the world. This article presents an experimental analysis of the utilization of modified expanded perlite and pumice as key constituents in the development of inorganic bonded fibrous composite boards. The study investigates the influence of these modified porous materials on the physical, mechanical, and thermal properties of the composite boards. For this purpose; composite mortars were produced using micronized quartz sand, a hybrid fiber consisting of cellulose and glass fiber, modified expanded perlite (MEP) with stearic acid (1, 2, 3, 4, 5, 6, 7, 8, 9 wt.%) and modified pumice (MPU) with stearic acid (1, 2, 3, 4, 5, 6, 7, 8, 9 wt.%). In order to make a comparison, a control mortar that did not contain modified expanded perlite and modified pumice was produced. Through a series of experiments, it is concluded that the density values of all other mixture designs with MEP and MPU aggregate additives under equivalent conditions are lower than the control sample. The water absorption values of the samples always remained below the control sample, and with the increase in the MPU ratio and decrease in the MEP ratio, the water absorption values of the samples also decreased. The average modulus of rupture (MOR) value of control sample in the analysis made after 14 days of curing under ambient conditions is 3.73 MPa. The highest MOR value of the test samples is 3.51 MPa, which is the mixture using the highest MPU. The thermal conductivity value of the control mixture is 0.352 W/mK. The thermal conductivity value of test mixtures with MEP and MPU aggregates varies between 0.175 W/mK and 0.287 W/mK.

Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering
Izmir Kâtip Çelebi University (TR)
Affordable and clean energy
Openalex Percentile: Top 88%
Natural Fiber Reinforced Composites
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.