Comparison of neck angle and musculoskeletal discomfort of surgeon in cataract surgery between three-dimensional heads-up display system and conventional microscope

The three-dimensional heads-up display system (3D HUDS) is increasingly utilized by ophthalmologists and suggested to offer ergonomic benefits compared to conventional operating microscopes. We aimed to quantitatively assess the surgeon's neck angle and musculoskeletal discomfort during cataract surgery using commercially available 3D HUDS and conventional microscope. In this single-center comparative observational study, the surgeon conducted routine phacoemulsification surgeries using Artevo® 800 and Opmi Lumera® 700 (both from Carl Zeiss Meditec, Jena, Germany). The surgeon's intraoperative neck angle was measured using the Cervical Range of Motion device. Postoperative musculoskeletal discomfort was assessed using the Visual Analog Scale (VAS) score after each surgery. A total of 80 cataract surgeries were analyzed, with 40 using Artevo® 800 and 40 using Opmi Lumera® 700. The neck angle was extended when using Artevo® 800 and flexed when using Opmi Lumera® 700 during continuous curvilinear capsulorhexis (CCC), phacoemulsification, and intraocular lens (IOL) placement (- 8.18 ± 2.85° vs. 8.27 ± 2.93° in CCC, - 7.83 ± 3.30° vs. 8.87 ± 2.83° in phacoemulsification, - 7.43 ± 3.80° vs. 7.67 ± 3.73° in IOL placement, respectively; all p < 0.001). The VAS score was significantly lower in surgeries performed with Artevo® 800 (1.27 ± 0.55 vs. 1.73 ± 0.64, p < 0.001). The findings suggest that 3D HUDS help reduce neck flexion and lower work-related musculoskeletal discomfort through ergonomic improvements.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-09-30
DOI
https://doi.org/10.1038/s41598-024-68630-1
Citations
1
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of neck angle and musculoskeletal discomfort of surgeon in cataract surgery between three-dimensional heads-up display system and conventional microscope

Bo Yi Kim, Youngsong Suh, Tae‐im Kim, Jiwon Jeong et al.
1 citations
Scientific Reports
Surgical Simulation and Training
0.57
article

Comparison of neck angle and musculoskeletal discomfort of surgeon in cataract surgery between three-dimensional heads-up display system and conventional microscope

Bo Yi Kim, Youngsong Suh, Tae‐im Kim, Jiwon Jeong, Su-Young Shin
article en
1 citations

Abstract

The three-dimensional heads-up display system (3D HUDS) is increasingly utilized by ophthalmologists and suggested to offer ergonomic benefits compared to conventional operating microscopes. We aimed to quantitatively assess the surgeon's neck angle and musculoskeletal discomfort during cataract surgery using commercially available 3D HUDS and conventional microscope. In this single-center comparative observational study, the surgeon conducted routine phacoemulsification surgeries using Artevo® 800 and Opmi Lumera® 700 (both from Carl Zeiss Meditec, Jena, Germany). The surgeon's intraoperative neck angle was measured using the Cervical Range of Motion device. Postoperative musculoskeletal discomfort was assessed using the Visual Analog Scale (VAS) score after each surgery. A total of 80 cataract surgeries were analyzed, with 40 using Artevo® 800 and 40 using Opmi Lumera® 700. The neck angle was extended when using Artevo® 800 and flexed when using Opmi Lumera® 700 during continuous curvilinear capsulorhexis (CCC), phacoemulsification, and intraocular lens (IOL) placement (- 8.18 ± 2.85° vs. 8.27 ± 2.93° in CCC, - 7.83 ± 3.30° vs. 8.87 ± 2.83° in phacoemulsification, - 7.43 ± 3.80° vs. 7.67 ± 3.73° in IOL placement, respectively; all p < 0.001). The VAS score was significantly lower in surgeries performed with Artevo® 800 (1.27 ± 0.55 vs. 1.73 ± 0.64, p < 0.001). The findings suggest that 3D HUDS help reduce neck flexion and lower work-related musculoskeletal discomfort through ergonomic improvements.

Scientific ReportsVol. 14(1)
Yonsei University (KR), Severance Hospital (KR), Naver (South Korea) (KR)
Korea Medical Device Development Fund, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 29%
Surgical Simulation and Training
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.