Dissolution method development and validation of brexpiprazole

A stability-indicating RP-HPLC method was established and validated for the determination of Brexpiprazole in bulk drug-using 1260 Infinity HPLC having column Hemochrom C-8, 25 cm X 4.6 mm x 5 µ, USP Apparatus Type II (Paddle), and sonicator. The prepared mobile phase was filtered as per the standard procedure. Analysis was carried out at wavelength 227 nm, flow rate 1ml per minute, 18-22 °C temperature, with an injection volume of 50 µl with time 21 minutes. It was found that interference of diluent and placebo is not more than 0.5% of Brexpiprazole. The individual % recovery was found to be between 97.0% to 100.0%, the linearity was within the range of 10- 60 µg mL with a Correlation Coefficient of 0.999, Slope of the regression line was found to be 1299178.9578 which means all parameters were found to be within range. In precision % RSD for % released dissolution values were found to be 99.16, in robustness, all the parameters like change in the flow rate, wavelength, and in RPM shows that the developed method was robust. The proposed approach performed well in terms of sensitivity, precision, accuracy, linearity and range, robustness. The well-known RP-HPLC method for the study of Brexpiprazole was shown to be trustworthy, as well as easy, consistent, cost-effective, and exact. For quality control or routine quantification, this method is applicable to determine Brexpiprazole in a bulk and pharmaceutical dosage form. This developed method required less time.

Authors

Publication Details

Journal
International Journal of Pharmaceutical Chemistry and Analysis
Published
2024-09-15
DOI
https://doi.org/10.18231/j.ijpca.2024.035
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dissolution method development and validation of brexpiprazole

Atul R. Bendale, Sushil Narkhede, Anil G. Jadhav, Vasim Pathan et al.
International Journal of Pharmaceutical Chemistry and Analysis
Analytical Methods in Pharmaceuticals
article

Dissolution method development and validation of brexpiprazole

Atul R. Bendale, Sushil Narkhede, Anil G. Jadhav, Vasim Pathan, Mansi Patole, Namrata Revar
article en

Abstract

A stability-indicating RP-HPLC method was established and validated for the determination of Brexpiprazole in bulk drug-using 1260 Infinity HPLC having column Hemochrom C-8, 25 cm X 4.6 mm x 5 µ, USP Apparatus Type II (Paddle), and sonicator. The prepared mobile phase was filtered as per the standard procedure. Analysis was carried out at wavelength 227 nm, flow rate 1ml per minute, 18-22 °C temperature, with an injection volume of 50 µl with time 21 minutes. It was found that interference of diluent and placebo is not more than 0.5% of Brexpiprazole. The individual % recovery was found to be between 97.0% to 100.0%, the linearity was within the range of 10- 60 µg mL with a Correlation Coefficient of 0.999, Slope of the regression line was found to be 1299178.9578 which means all parameters were found to be within range. In precision % RSD for % released dissolution values were found to be 99.16, in robustness, all the parameters like change in the flow rate, wavelength, and in RPM shows that the developed method was robust. The proposed approach performed well in terms of sensitivity, precision, accuracy, linearity and range, robustness. The well-known RP-HPLC method for the study of Brexpiprazole was shown to be trustworthy, as well as easy, consistent, cost-effective, and exact. For quality control or routine quantification, this method is applicable to determine Brexpiprazole in a bulk and pharmaceutical dosage form. This developed method required less time.

International Journal of Pharmaceutical Chemistry and AnalysisVol. 11(3)
Openalex Percentile: Top 85%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.