2613 Diagnostic accuracy of the aortic dissection detection risk score alone or with D-dimer for acute aortic syndromes: systematic review and meta-analysis

<h3>Aims and Objectives</h3> Acute aortic syndrome (AAS) is an uncommon but life-threatening diagnosis. Symptoms suggesting AAS are very common, so clinical scores and blood tests may be needed to select patients for definitive imaging. We aimed to evaluate the diagnostic accuracy of the aortic dissection detection risk score (ADD-RS) used alone or in combination with D-dimer for detecting AAS in patients presenting with symptoms suggestive of AAS. <h3>Method and Design</h3> We searched MEDLINE, EMBASE, and the Cochrane Library from inception to February 2024, along with the reference lists of included studies and other systematic reviews. All diagnostic accuracy studies that assessed the use of ADD-RS alone or with D-Dimer for diagnosing AAS compared with a reference standard test were included. Two reviewers independently selected and extracted data. Risk of bias was appraised using QUADAS-2 tool. Data were synthesised using hierarchical meta-analysis models. <h3>Results and Conclusion</h3> We selected 13 studies from the 2017 citations identified, including six studies evaluating combinations of ADD-RS alongside D-dimer&gt;500ng/L. The methodological quality of the included studies was variable, with most studies having low or unclear risk of bias and applicability concerns in at least one item of the QUADAS-2 tool. The table shows the summary sensitivities and specificities (with 95% credible and predictive intervals) of ADD-RS at thresholds of greater than zero and greater than one, and combinations of the ADD-RS and D-dimer. The ADD-RS can be used alone or alongside D-dimer to identify AAS with a range of trade-offs between sensitivity (93.1% to 99.8%) and specificity (21.8% to 67.1%). A combination based on the Canadian Clinical Practice Guideline may represent the best trade-off, with sensitivity of 93.1% and specificity of 67.1% for AAS.

Authors

Institutions

Publication Details

Published
2024-09-30
DOI
https://doi.org/10.1136/emermed-2024-rcem.14
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

2613 Diagnostic accuracy of the aortic dissection detection risk score alone or with D-dimer for acute aortic syndromes: systematic review and meta-analysis

Shijie Ren, Rachel McLatchie, Steve Goodacre, Munira Essat et al.
Aortic Disease and Treatment Approaches
article

2613 Diagnostic accuracy of the aortic dissection detection risk score alone or with D-dimer for acute aortic syndromes: systematic review and meta-analysis

Shijie Ren, Rachel McLatchie, Steve Goodacre, Munira Essat, Eduardo Bossone, Abdullah Pandor, Mark Clowes, Sa Ren, Paolo Bima, Mamoru Toyofuku, Sarah L Wilson
article en

Abstract

<h3>Aims and Objectives</h3> Acute aortic syndrome (AAS) is an uncommon but life-threatening diagnosis. Symptoms suggesting AAS are very common, so clinical scores and blood tests may be needed to select patients for definitive imaging. We aimed to evaluate the diagnostic accuracy of the aortic dissection detection risk score (ADD-RS) used alone or in combination with D-dimer for detecting AAS in patients presenting with symptoms suggestive of AAS. <h3>Method and Design</h3> We searched MEDLINE, EMBASE, and the Cochrane Library from inception to February 2024, along with the reference lists of included studies and other systematic reviews. All diagnostic accuracy studies that assessed the use of ADD-RS alone or with D-Dimer for diagnosing AAS compared with a reference standard test were included. Two reviewers independently selected and extracted data. Risk of bias was appraised using QUADAS-2 tool. Data were synthesised using hierarchical meta-analysis models. <h3>Results and Conclusion</h3> We selected 13 studies from the 2017 citations identified, including six studies evaluating combinations of ADD-RS alongside D-dimer&gt;500ng/L. The methodological quality of the included studies was variable, with most studies having low or unclear risk of bias and applicability concerns in at least one item of the QUADAS-2 tool. The table shows the summary sensitivities and specificities (with 95% credible and predictive intervals) of ADD-RS at thresholds of greater than zero and greater than one, and combinations of the ADD-RS and D-dimer. The ADD-RS can be used alone or alongside D-dimer to identify AAS with a range of trade-offs between sensitivity (93.1% to 99.8%) and specificity (21.8% to 67.1%). A combination based on the Canadian Clinical Practice Guideline may represent the best trade-off, with sensitivity of 93.1% and specificity of 67.1% for AAS.

Wexham Park Hospital (GB), Edinburgh Royal Infirmary (GB), Japanese Red Cross Society Wakayama Medical Center (JP), University of Turin (IT), University of Sheffield (GB)
Openalex Percentile: Top 69%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.