Enhancing Pregnancy Care: Harnessing Label‐Free Immunosensors for Pre‐Eclampsia Detection Using PdNPs/Poly(3,5‐Diaminobenzoic Acid) Modified Glassy Carbon Electrodes

Abstract Placental Growth factor (PlGF) is one of the biomarkers useful for detecting pregnancy hypertension disorder, Pre‐eclampsia. Herein, we focus on developing a label‐free immunosensor using simple electrochemical methods to detect PlGF antigens for pre‐eclampsia diagnosis. The work includes the electrochemical deposition of Palladium nanoparticles (PdNPs) on the glassy carbon electrode (GCE) surface using amperometry followed by electropolymerization of diaminobenzoic acid (DABA) onto the PdNPs/GCE. Antibody (aPlGF) was covalently immobilized on the pDABA/PdNPs/GCE using EDC/NHS reaction. The interaction of the antibody with the antigen was measured using differential pulse voltammetric technique. The linear range obtained for the immunosensor is 1–25 ng mL −1 with a limit of detection of 53 pg mL −1 . The stability and reproducibility of the sensor were obtained in the acceptable range. The developed sensor was used to detect PlGF antigen in artificial blood and urine samples by spike recovery analysis.

Authors

Institutions

Publication Details

Journal
ChemistrySelect
Published
2024-09-30
DOI
https://doi.org/10.1002/slct.202401495
Citations
4
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.94

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Pregnancy Care: Harnessing Label‐Free Immunosensors for Pre‐Eclampsia Detection Using PdNPs/Poly(3,5‐Diaminobenzoic Acid) Modified Glassy Carbon Electrodes

Tripti S Warrier, Sithara Soman, Kala Ramakrishnan
4 citations
ChemistrySelect
Advanced biosensing and bioanalysis techniques
0.94
article

Enhancing Pregnancy Care: Harnessing Label‐Free Immunosensors for Pre‐Eclampsia Detection Using PdNPs/Poly(3,5‐Diaminobenzoic Acid) Modified Glassy Carbon Electrodes

Tripti S Warrier, Sithara Soman, Kala Ramakrishnan
article en
4 citations

Abstract

Abstract Placental Growth factor (PlGF) is one of the biomarkers useful for detecting pregnancy hypertension disorder, Pre‐eclampsia. Herein, we focus on developing a label‐free immunosensor using simple electrochemical methods to detect PlGF antigens for pre‐eclampsia diagnosis. The work includes the electrochemical deposition of Palladium nanoparticles (PdNPs) on the glassy carbon electrode (GCE) surface using amperometry followed by electropolymerization of diaminobenzoic acid (DABA) onto the PdNPs/GCE. Antibody (aPlGF) was covalently immobilized on the pDABA/PdNPs/GCE using EDC/NHS reaction. The interaction of the antibody with the antigen was measured using differential pulse voltammetric technique. The linear range obtained for the immunosensor is 1–25 ng mL −1 with a limit of detection of 53 pg mL −1 . The stability and reproducibility of the sensor were obtained in the acceptable range. The developed sensor was used to detect PlGF antigen in artificial blood and urine samples by spike recovery analysis.

ChemistrySelectVol. 9(37)
Cochin University of Science and Technology (IN), Inter-University Accelerator Centre (IN)
Department of Science and Technology, Ministry of Science and Technology, India, Cochin University of Science and Technology, Science and Engineering Research Board
Openalex Percentile: Top 25%
Advanced biosensing and bioanalysis techniques
0.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.