Comparative Evaluation of Neural Network Models for Optimizing ECG Signal in Non-Uniform Sampling Domain

Electrocardiographic signals (ECG) are ubiquitous, which justifies the research of their optimal storage and transmission. However, proposals for non-uniform signal sampling must take into account the priority of diagnostic data accuracy and record integrity, as well as robustness to noise and interference. In this study, two novel methods are introduced, each utilizing a distinct neural network architecture for optimizing non-uniform sampling of ECG signal. A transformer model refines each time point selection through an iterative process using gradient descent optimization, with the goal of minimizing the mean squared error between the original and resampled signals. It adaptively modifies time points, which improves the alignment between both signals. In contrast, the Temporal Convolutional Network model trains on the original signal, and gradient descent optimization is utilized to improve the selection of time points. Evaluation of both strategies’ efficacy is performed by calculating signal distances at lower and higher sampling rates. First, a collection of synthetic data points that resembled the P-QRS-T wave was used to train the model. Then, the ECG-ID database for real data analysis was used. Filtering to remove baseline wander followed by evaluation and testing were carried out in the real patient data. The results, in particular MSE = 0.0005, RMSE = 0.0216, and Pearson’s CC = 0.9904 for 120 sps in the case of the transformer patient data model, provide viable paths for maintaining the precision and dependability of ECG-based diagnostic systems at much lower sampling rate. Outcomes indicate that both techniques are effective at improving the fidelity between the original and modified ECG signals.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-09-28
DOI
https://doi.org/10.3390/app14198772
Citations
1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Evaluation of Neural Network Models for Optimizing ECG Signal in Non-Uniform Sampling Domain

Piotr Augustyniak, Pratixita Bhattacharjee
1 citations
Applied Sciences
ECG Monitoring and Analysis
0.40
article

Comparative Evaluation of Neural Network Models for Optimizing ECG Signal in Non-Uniform Sampling Domain

Piotr Augustyniak, Pratixita Bhattacharjee
article en
1 citations

Abstract

Electrocardiographic signals (ECG) are ubiquitous, which justifies the research of their optimal storage and transmission. However, proposals for non-uniform signal sampling must take into account the priority of diagnostic data accuracy and record integrity, as well as robustness to noise and interference. In this study, two novel methods are introduced, each utilizing a distinct neural network architecture for optimizing non-uniform sampling of ECG signal. A transformer model refines each time point selection through an iterative process using gradient descent optimization, with the goal of minimizing the mean squared error between the original and resampled signals. It adaptively modifies time points, which improves the alignment between both signals. In contrast, the Temporal Convolutional Network model trains on the original signal, and gradient descent optimization is utilized to improve the selection of time points. Evaluation of both strategies’ efficacy is performed by calculating signal distances at lower and higher sampling rates. First, a collection of synthetic data points that resembled the P-QRS-T wave was used to train the model. Then, the ECG-ID database for real data analysis was used. Filtering to remove baseline wander followed by evaluation and testing were carried out in the real patient data. The results, in particular MSE = 0.0005, RMSE = 0.0216, and Pearson’s CC = 0.9904 for 120 sps in the case of the transformer patient data model, provide viable paths for maintaining the precision and dependability of ECG-based diagnostic systems at much lower sampling rate. Outcomes indicate that both techniques are effective at improving the fidelity between the original and modified ECG signals.

Applied SciencesVol. 14(19)
Jagiellonian University (PL), AGH University of Krakow (PL)
Akademia Górniczo-Hutnicza im. Stanislawa Staszica
Openalex Percentile: Top 32%
ECG Monitoring and Analysis
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative Evaluation of Neural Network Models for Optimizing ECG Signal in Non-Uniform Sampling Domain — Piotr Augustyniak, Pratixita Bhattacharjee · Applied Sciences (2024) | TGRS Research Map | TGRS