Experimental Full-Scale Progressive Collapse Test of a 3D Steel-Frame Substructure with RC Slabs

This paper presents an experimental study on the progressive collapse behavior of a full-scale three-dimensional (3D) steel frame substructure with cast-in-place reinforced concrete (RC) floor slabs. A full-scale specimen and relatively large-span RC floor slabs were the two main features of the experimental test. The alternate load path (ALP) method was chosen as the research approach, with one external column being removed before testing. A specially designed 12-point loading system was employed to load the specimen quasi-statically, allowing the acquisition of the load-displacement response and failure process of the test specimen from the initiation of loading to the final collapse. Additionally, based on the test, the deformations of structural members, contributions of various load-resisting mechanisms, load redistribution among the remaining parts of the structure, and dynamic response were analyzed. The ultimate collapse resistance of the structure was theoretically predicted based on the yield line and plastic hinge theories. The test and analysis results led to the following findings: One, the typical steel frame structure in this study, designed based on current steel structure codes, withstood the failure of an external column. Two, tensile membrane action (TMA) primarily developed in the floor slab parallel to the double-span beam above the removed column. Three, flexural action (FA) was the main contributor to resisting the vertical loads throughout the loading process. Its contribution reached up to 88% at the structural ultimate load-carrying capacity position. However, before the final failure of the structure, the loads resisted by catenary action (CA) in beams and TMA in floor slabs could not be ignored. The sum of the two accounted for one-third of the total vertical loads. Four, Columns C1 and C2, directly connected to the removed column through the double-span beam B1-B2, sustained the majority of the vertical loads. Five, for steel frame structures with rigid or semi-rigid connections characterized by good moment resistance but limited rotational capacity, strengthening the connection via additional measures to ensure full development of CA in beams at large deformation stage may be the key to enhancing structural resistance to progressive collapse.

Authors

Institutions

Publication Details

Journal
Journal of Structural Engineering
Published
2024-09-30
DOI
https://doi.org/10.1061/jsendh.steng-13551
Citations
7
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
1.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Full-Scale Progressive Collapse Test of a 3D Steel-Frame Substructure with RC Slabs

Bo Yang, Kang Chen, De-Yang Kong, Jie-Peng Liu et al.
7 citations
Journal of Structural Engineering
Structural Response to Dynamic Loads
1.83
article

Experimental Full-Scale Progressive Collapse Test of a 3D Steel-Frame Substructure with RC Slabs

Bo Yang, Kang Chen, De-Yang Kong, Jie-Peng Liu, Lu-Ming Ren
article en
7 citations

Abstract

This paper presents an experimental study on the progressive collapse behavior of a full-scale three-dimensional (3D) steel frame substructure with cast-in-place reinforced concrete (RC) floor slabs. A full-scale specimen and relatively large-span RC floor slabs were the two main features of the experimental test. The alternate load path (ALP) method was chosen as the research approach, with one external column being removed before testing. A specially designed 12-point loading system was employed to load the specimen quasi-statically, allowing the acquisition of the load-displacement response and failure process of the test specimen from the initiation of loading to the final collapse. Additionally, based on the test, the deformations of structural members, contributions of various load-resisting mechanisms, load redistribution among the remaining parts of the structure, and dynamic response were analyzed. The ultimate collapse resistance of the structure was theoretically predicted based on the yield line and plastic hinge theories. The test and analysis results led to the following findings: One, the typical steel frame structure in this study, designed based on current steel structure codes, withstood the failure of an external column. Two, tensile membrane action (TMA) primarily developed in the floor slab parallel to the double-span beam above the removed column. Three, flexural action (FA) was the main contributor to resisting the vertical loads throughout the loading process. Its contribution reached up to 88% at the structural ultimate load-carrying capacity position. However, before the final failure of the structure, the loads resisted by catenary action (CA) in beams and TMA in floor slabs could not be ignored. The sum of the two accounted for one-third of the total vertical loads. Four, Columns C1 and C2, directly connected to the removed column through the double-span beam B1-B2, sustained the majority of the vertical loads. Five, for steel frame structures with rigid or semi-rigid connections characterized by good moment resistance but limited rotational capacity, strengthening the connection via additional measures to ensure full development of CA in beams at large deformation stage may be the key to enhancing structural resistance to progressive collapse.

Journal of Structural EngineeringVol. 150(12)
Chongqing University (CN), National University of Singapore (SG), Xi’an Jiaotong-Liverpool University (CN)
Sustainable cities and communities
Openalex Percentile: Top 16%
Structural Response to Dynamic Loads
1.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.