Nonlinear Calibration and Temperature Sensitivity of Makrofol Solid-State Nuclear Track Detectors for Radon Measurement

A key characteristic of a solid-state nuclear track detector (SSNTD) is that as more alpha tracks accumulate on the detector, the likelihood of track overlap will increase, making it difficult to distinguish individual events. This article presents the calibration of an in-house SSNTD using a Makrofol polycarbonate detector and electrochemical etching. The calibration employs a nonlinear log-logistic quantile function, which is nearly linear at low exposures but accounts for the reduced efficiency at high exposures due to overlapping alpha tracks. The function can be fitted to calibration measurements very accurately, eliminating systematic errors previously associated with the method at certain radon exposures. This article explores the uncertainties and detection limits associated with the calibration and outlines methods for their evaluation. Additionally, it includes a preliminary discussion on the method’s sensitivity to temperature.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2024-09-30
DOI
https://doi.org/10.3390/atmos15101179
Citations
4
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
2.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nonlinear Calibration and Temperature Sensitivity of Makrofol Solid-State Nuclear Track Detectors for Radon Measurement

Tuukka Turtiainen, Jussi-Pekka Laine, Salla Rantanen, Tiina Oinas
4 citations
Atmosphere
Radiation Detection and Scintillator Technologies
2.43
article

Nonlinear Calibration and Temperature Sensitivity of Makrofol Solid-State Nuclear Track Detectors for Radon Measurement

Tuukka Turtiainen, Jussi-Pekka Laine, Salla Rantanen, Tiina Oinas
article en
4 citations

Abstract

A key characteristic of a solid-state nuclear track detector (SSNTD) is that as more alpha tracks accumulate on the detector, the likelihood of track overlap will increase, making it difficult to distinguish individual events. This article presents the calibration of an in-house SSNTD using a Makrofol polycarbonate detector and electrochemical etching. The calibration employs a nonlinear log-logistic quantile function, which is nearly linear at low exposures but accounts for the reduced efficiency at high exposures due to overlapping alpha tracks. The function can be fitted to calibration measurements very accurately, eliminating systematic errors previously associated with the method at certain radon exposures. This article explores the uncertainties and detection limits associated with the calibration and outlines methods for their evaluation. Additionally, it includes a preliminary discussion on the method’s sensitivity to temperature.

AtmosphereVol. 15(10)
Radiation and Nuclear Safety Authority (FI)
Openalex Percentile: Top 12%
Radiation Detection and Scintillator Technologies
2.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nonlinear Calibration and Temperature Sensitivity of Makrofol Solid-State Nuclear Track Detectors for Radon Measurement — Tuukka Turtiainen, Jussi-Pekka Laine, et al. · Atmosphere (2024) | TGRS Research Map | TGRS