Determination of valsartan drug by ion pair complex formation method in tablet form

A rapid, simple, sensitive, spectroscopic, ion pair complex method was developed for valsartan (VAL ) in pharmaceutical forms. Resazurin dye was used to form an ion pairing complex with the drug valsartan. analytical characteristics of the proposed method are Beer’s law range =10-60 (μg/mL), correlation coefficient (R2) = 0.9976 , limit of detection (LOD) = 0.1076(µg/mL), limit of quantification (LOQ) = 0.3261 (µg/mL), recovery percentage (%Rec) = (101.9626% - 95.6074%), relative standard deviation (%RSD)= 0.6188% - 0.7148%, Molar absorption (ε)= 4659.85(L/mol.cm), Sandell's index(S) = 0.093458(μg/cm2),at wavelength 495 nm . The results showed high accuracy and precision of the proposed quantification method for the valsartan drug , and it was of high accuracy and consistent.

Authors

Institutions

Publication Details

Journal
Iraqi journal for applied science.
Published
2024-09-30
DOI
https://doi.org/10.69923/851hfy94
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of valsartan drug by ion pair complex formation method in tablet form

Eman Thiab Al-Samarrai, Qaaed Baker Ali
Iraqi journal for applied science.
Analytical Methods in Pharmaceuticals
article

Determination of valsartan drug by ion pair complex formation method in tablet form

Eman Thiab Al-Samarrai, Qaaed Baker Ali
article en

Abstract

A rapid, simple, sensitive, spectroscopic, ion pair complex method was developed for valsartan (VAL ) in pharmaceutical forms. Resazurin dye was used to form an ion pairing complex with the drug valsartan. analytical characteristics of the proposed method are Beer’s law range =10-60 (μg/mL), correlation coefficient (R2) = 0.9976 , limit of detection (LOD) = 0.1076(µg/mL), limit of quantification (LOQ) = 0.3261 (µg/mL), recovery percentage (%Rec) = (101.9626% - 95.6074%), relative standard deviation (%RSD)= 0.6188% - 0.7148%, Molar absorption (ε)= 4659.85(L/mol.cm), Sandell's index(S) = 0.093458(μg/cm2),at wavelength 495 nm . The results showed high accuracy and precision of the proposed quantification method for the valsartan drug , and it was of high accuracy and consistent.

Iraqi journal for applied science.Vol. 1(2)
University of Samarra (IQ)
Openalex Percentile: Top 85%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.