Experimental Characterization of a Bladeless Air Compressor

Abstract The Tesla compressor is an innovative technology that offers a unique approach to fluid compression. Unlike traditional compressors that use rotating blades, bladeless compressors utilize closely spaced disks to create compression. The purpose of this article is to design a prototype Tesla air compressor with optimal design parameters and investigate the performance and loss characteristics based on numerical analysis and experimental demonstration. The prototype model has been numerically investigated at different rotational speeds, and the results have been compared with those obtained in experiments. Computational fluid dynamics (CFD) simulations indicate that the rotor-only efficiency is greater than 90% at very low mass flowrates, while the coupling of the rotor and volute leads to a total-to-static efficiency of approximately 58% (without losses) at 14 g/s. At a nominal mass flow of 4 g/s, the highest total-to-static pressure ratio would be around 1.27. Experimental results indicate leakage losses greatly reduce net mass flow, while pressure ratio values are in good agreement with CFD predictions. During this experiment, a maximum isentropic efficiency of 32.4% is measured. Indeed, the prototype included ventilation and leakage losses, which were not modeled in the CFD analysis. It is remarkable that the compressor does not show any unstable behavior down to zero mass flow (closed valve test), where the CFD and the experiment show consistent pressure ratios. An estimation of the losses from end-wall friction and leakage flow is carried out using numerical simulations at different exit radial clearances. Increasing radial clearance results in an increase in leakage and end-wall power loss, the latter being driven mainly by the axial clearance with the casing, which remained unchanged. To minimize leakage, a Teflon ring has been used as a first measure. Numerical calculations have indicated that the leakage rate is approximately 6 g/s at design speed. A brush seal-type solution can improve the sealing system to reduce leakage.

Authors

Institutions

Publication Details

Journal
Journal of Engineering for Gas Turbines and Power
Published
2024-09-30
DOI
https://doi.org/10.1115/1.4066732
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Characterization of a Bladeless Air Compressor

Alberto Traverso, Ravi Nath Tiwari, Ward De Paepe, Federico Reggio et al.
1 links
Journal of Engineering for Gas Turbines and Power
Refrigeration and Air Conditioning Technologies
article

Experimental Characterization of a Bladeless Air Compressor

Alberto Traverso, Ravi Nath Tiwari, Ward De Paepe, Federico Reggio, Mario L. Ferrari
article en

Abstract

Abstract The Tesla compressor is an innovative technology that offers a unique approach to fluid compression. Unlike traditional compressors that use rotating blades, bladeless compressors utilize closely spaced disks to create compression. The purpose of this article is to design a prototype Tesla air compressor with optimal design parameters and investigate the performance and loss characteristics based on numerical analysis and experimental demonstration. The prototype model has been numerically investigated at different rotational speeds, and the results have been compared with those obtained in experiments. Computational fluid dynamics (CFD) simulations indicate that the rotor-only efficiency is greater than 90% at very low mass flowrates, while the coupling of the rotor and volute leads to a total-to-static efficiency of approximately 58% (without losses) at 14 g/s. At a nominal mass flow of 4 g/s, the highest total-to-static pressure ratio would be around 1.27. Experimental results indicate leakage losses greatly reduce net mass flow, while pressure ratio values are in good agreement with CFD predictions. During this experiment, a maximum isentropic efficiency of 32.4% is measured. Indeed, the prototype included ventilation and leakage losses, which were not modeled in the CFD analysis. It is remarkable that the compressor does not show any unstable behavior down to zero mass flow (closed valve test), where the CFD and the experiment show consistent pressure ratios. An estimation of the losses from end-wall friction and leakage flow is carried out using numerical simulations at different exit radial clearances. Increasing radial clearance results in an increase in leakage and end-wall power loss, the latter being driven mainly by the axial clearance with the casing, which remained unchanged. To minimize leakage, a Teflon ring has been used as a first measure. Numerical calculations have indicated that the leakage rate is approximately 6 g/s at design speed. A brush seal-type solution can improve the sealing system to reduce leakage.

Journal of Engineering for Gas Turbines and PowerVol. 147(4)
University of Mons (BE), University of Genoa (IT)
Openalex Percentile: Top 84%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.