Flashover Features in Aircraft Cargo Compartment at Low Pressure

The flashover mechanism in an aircraft cargo compartment under low pressure was investigated in this study. A series of fire experiments were conducted in a scale model of a one-quarter volume FAA standard aircraft cargo compartment at 96 kPa and 60 kPa. The ignition of single-walled corrugated cardboard was chosen as the criterion of the flashover. The influence of different fire sizes and fuel types on the flashover was studied by comparing the average temperature of the smoke layer, the radiation heat flux at the floor level, and the heat release rate of the fire source. The critical condition and behavior of the flashover were analyzed. The results show that under low pressure, the flashover occurs at a higher temperature and radiation heat flux. Increasing the fire source size brings the flashover forward. At 60 kPa and 96 kPa, the cardboard ignites under a flashover when the average temperature of the smoke layer reaches 551 °C and 450 °C, and the average radiant heat flux at the floor level reaches 19.6 kW/m2 and 14 kW/m2, respectively. In addition, the minimum fire size for a flashover is directly proportional to the heat of evaporation and inversely proportional to the heat of combustion.

Authors

Institutions

Publication Details

Journal
Fire
Published
2024-09-30
DOI
https://doi.org/10.3390/fire7100350
Citations
2
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
2.60
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flashover Features in Aircraft Cargo Compartment at Low Pressure

Yuanhua He, Jingdong Wang, Zitong Li, Jiang Huang
2 citations
Fire
Combustion and Detonation Processes
2.60
article

Flashover Features in Aircraft Cargo Compartment at Low Pressure

Yuanhua He, Jingdong Wang, Zitong Li, Jiang Huang
article en
2 citations

Abstract

The flashover mechanism in an aircraft cargo compartment under low pressure was investigated in this study. A series of fire experiments were conducted in a scale model of a one-quarter volume FAA standard aircraft cargo compartment at 96 kPa and 60 kPa. The ignition of single-walled corrugated cardboard was chosen as the criterion of the flashover. The influence of different fire sizes and fuel types on the flashover was studied by comparing the average temperature of the smoke layer, the radiation heat flux at the floor level, and the heat release rate of the fire source. The critical condition and behavior of the flashover were analyzed. The results show that under low pressure, the flashover occurs at a higher temperature and radiation heat flux. Increasing the fire source size brings the flashover forward. At 60 kPa and 96 kPa, the cardboard ignites under a flashover when the average temperature of the smoke layer reaches 551 °C and 450 °C, and the average radiant heat flux at the floor level reaches 19.6 kW/m2 and 14 kW/m2, respectively. In addition, the minimum fire size for a flashover is directly proportional to the heat of evaporation and inversely proportional to the heat of combustion.

FireVol. 7(10)
Civil Aviation Flight University of China (CN)
Openalex Percentile: Top 8%
Combustion and Detonation Processes
2.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.