Conjugate Heat Transfer Validation of an Optimized Film Cooling Configuration for a Turbine Vane Endwall

Abstract In this study, to improve overall cooling performance for the endwall of a turbine nozzle guide vane that incorporated internal jet impingement and external purge flow and discrete injection cooling, the external film cooling was re-designed based on the knowledge of film coverage patterns from a baseline design, allowing film injection to overcome the crossflow and to cover more areas of the endwall with a given amount of coolant. Experimental conjugate heat transfer validation of the newly designed cooling geometry was conducted in a linear vane cascade by measuring overall cooling effectiveness over the endwall through an infrared (IR) thermography technique and detecting aero-thermal fields at the cascade exit with five-hole and thermocouple probes. For a given total coolant flowrate, the influence of coolant split among different cooling sources was examined. Additionally, parallel computational simulations were undertaken to elaborate the results observed in the experiments by offering in-passage flow physics. Comparisons with the baseline design proved that the newly designed cooling scheme improved the endwall overall cooling performance in terms of both effectiveness levels and coverage. In addition to optimizing the cooling geometry, more efficient usage of the coolant was found to be linked with the proper coolant split, which helped the re-designed cooling geometry to achieve an improvement of cooling effectiveness by approximately 20%. The computational simulations produced satisfactory overall cooling effectiveness, but failed to capture mixing of coolant with mainstream flow. The coolant with mainstream flow interactions visualized by the simulations provided evidence that the coolant jets from the optimized cooling scheme increased mixing flow loss but those from the pressure side suppressed the inherent vortex flow, resulting in no aerodynamic penalty as compared with the baseline cooling design.

Authors

Institutions

Publication Details

Journal
Journal of Turbomachinery
Published
2024-09-30
DOI
https://doi.org/10.1115/1.4066739
Citations
2
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conjugate Heat Transfer Validation of an Optimized Film Cooling Configuration for a Turbine Vane Endwall

Zhenping Feng, Xing Yang, Hang Wu
2 citations
Journal of Turbomachinery
Heat Transfer Mechanisms
0.43
article

Conjugate Heat Transfer Validation of an Optimized Film Cooling Configuration for a Turbine Vane Endwall

Zhenping Feng, Xing Yang, Hang Wu
article en
2 citations

Abstract

Abstract In this study, to improve overall cooling performance for the endwall of a turbine nozzle guide vane that incorporated internal jet impingement and external purge flow and discrete injection cooling, the external film cooling was re-designed based on the knowledge of film coverage patterns from a baseline design, allowing film injection to overcome the crossflow and to cover more areas of the endwall with a given amount of coolant. Experimental conjugate heat transfer validation of the newly designed cooling geometry was conducted in a linear vane cascade by measuring overall cooling effectiveness over the endwall through an infrared (IR) thermography technique and detecting aero-thermal fields at the cascade exit with five-hole and thermocouple probes. For a given total coolant flowrate, the influence of coolant split among different cooling sources was examined. Additionally, parallel computational simulations were undertaken to elaborate the results observed in the experiments by offering in-passage flow physics. Comparisons with the baseline design proved that the newly designed cooling scheme improved the endwall overall cooling performance in terms of both effectiveness levels and coverage. In addition to optimizing the cooling geometry, more efficient usage of the coolant was found to be linked with the proper coolant split, which helped the re-designed cooling geometry to achieve an improvement of cooling effectiveness by approximately 20%. The computational simulations produced satisfactory overall cooling effectiveness, but failed to capture mixing of coolant with mainstream flow. The coolant with mainstream flow interactions visualized by the simulations provided evidence that the coolant jets from the optimized cooling scheme increased mixing flow loss but those from the pressure side suppressed the inherent vortex flow, resulting in no aerodynamic penalty as compared with the baseline cooling design.

Journal of TurbomachineryVol. 147(3)
Xi'an Jiaotong University (CN)
Ministry of Industry and Information Technology of the People's Republic of China
Openalex Percentile: Top 42%
Heat Transfer Mechanisms
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.