The Data Acquisition System of WEST’s New Thomson Scattering Diagnostics

WEST, the Tungsten Environment in Steady-state Tokamak at IRFM (France), is currently being equipped with two new plasma-monitoring systems based on Thomson scattering. Nearly 50 optical viewing lines will be installed to collect scattered light near the core plasma region and in the plasma pedestal. The collected light pulses are forwarded along optical fiber bundles to polychromators where they are optically filtered into five channels and converted to swift electrical pulses. A custom fast digitizer board adapted to the polychromators was designed to capture these signals. This Nectarine board provides six triggered fast channels to catch the scattered pulse shape at 1–3.2 GS/s, thanks to three Nectar chips. Six additional ADC channels provide a slower sampling rate for background monitoring. This contribution describes and discusses the performances of the real-time data acquisition and processing system (PS), especially the Nectarine board, designed specifically for WEST’s new Thomson scattering diagnostics (TSDs).

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2024-09-30
DOI
https://doi.org/10.1109/tns.2024.3470868
Citations
4
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
5.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Data Acquisition System of WEST’s New Thomson Scattering Diagnostics

A. Barbuti, E. Delagnes, Benoît de Saint Vincent, R. Sabot et al.
4 citations
IEEE Transactions on Nuclear Science
Spacecraft and Cryogenic Technologies
5.20
article

The Data Acquisition System of WEST’s New Thomson Scattering Diagnostics

A. Barbuti, E. Delagnes, Benoît de Saint Vincent, R. Sabot, C. Bouchand, N. Fedorczak, G. Colledani, G. Moureau, L. Schiesko, Alexandre Magnino, Y. Moudden, Thomas Chaminade, M. Carole
article en
4 citations

Abstract

WEST, the Tungsten Environment in Steady-state Tokamak at IRFM (France), is currently being equipped with two new plasma-monitoring systems based on Thomson scattering. Nearly 50 optical viewing lines will be installed to collect scattered light near the core plasma region and in the plasma pedestal. The collected light pulses are forwarded along optical fiber bundles to polychromators where they are optically filtered into five channels and converted to swift electrical pulses. A custom fast digitizer board adapted to the polychromators was designed to capture these signals. This Nectarine board provides six triggered fast channels to catch the scattered pulse shape at 1–3.2 GS/s, thanks to three Nectar chips. Six additional ADC channels provide a slower sampling rate for background monitoring. This contribution describes and discusses the performances of the real-time data acquisition and processing system (PS), especially the Nectarine board, designed specifically for WEST’s new Thomson scattering diagnostics (TSDs).

IEEE Transactions on Nuclear ScienceVol. 72(3)
Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), CEA Cadarache (FR), CEA Paris-Saclay (FR), Institut de Recherche sur les Lois Fondamentales de l'Univers (FR)
Industry, innovation and infrastructure
Openalex Percentile: Top 5%
Spacecraft and Cryogenic Technologies
5.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Data Acquisition System of WEST’s New Thomson Scattering Diagnostics — A. Barbuti, E. Delagnes, et al. · IEEE Transactions on Nuclear Science (2024) | TGRS Research Map | TGRS