Evolution characteristics of an induced electric charge signal and identification method of charge for instability failure in loaded coal

A coal-loaded charge induction monitoring system is developed to effectively forecast the dynamic disasters caused by coal failure. Specifically, a digital finite impulse response (FIR) filter is designed to denoise and filter the signal, and the time-frequency domain evolution of induced charge signals is analyzed during coal failure experiments. The quantitative relationships between the induced electric charge and stress-strain energy, and ultimately, between induced electric charge and coal deformation/failure, are revealed. Ultimately, the electric charge sensor exhibits high signal collection frequency and high sensitivity, and the FIR low-pass filter constructed in MATLAB effectively denoises and filters induced charge signals. The main frequency range of the white noise is 50–500 Hz, and the main frequency of the charge signal induced by coal deformation and failure is concentrated in the range of 0–50 Hz. The optimal distances for monitoring cubic and cylindrical raw coal samples using this sensor are 9 mm and 11 mm, respectively. Notably, strain energy is released faster when it can dissipate more readily, and induced charge pulses become denser when more intense signals produce large fluctuations. A method is proposed to identify coal deformation and failure based on changes in the induced electric charge. This study provides a new means of monitoring the early warning signs of dynamic coal mine disasters. Based on our experimental results and conclusions, a new method is proposed to identify coal deformation and failure based on changes in the induced electric charge. The precursor to the moment of coal failure can be identified by monitoring the amplitude of the induced charge, the dynamic trend of fluctuation, and the cumulative number of induced electric charge pulses during the process of coal deformation.

Authors

Institutions

Publication Details

Journal
Journal of Rock Mechanics and Geotechnical Engineering
Published
2024-09-30
DOI
https://doi.org/10.1016/j.jrmge.2024.08.022
Citations
8
Primary Topic
Earthquake Detection and Analysis
Type
article
Field-Weighted Citation Impact
4.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evolution characteristics of an induced electric charge signal and identification method of charge for instability failure in loaded coal

Shuwei Hu, Hao Luo, Yonghui Xiao, Hongbin Li et al.
8 citations
Journal of Rock Mechanics and Geotechnical Engineering
Earthquake Detection and Analysis
4.28
article

Evolution characteristics of an induced electric charge signal and identification method of charge for instability failure in loaded coal

Shuwei Hu, Hao Luo, Yonghui Xiao, Hongbin Li, Xiaoliang Li, Wei Wang, Like Zhao, Yishan Pan, Xueqi Zhang
article en
8 citations

Abstract

A coal-loaded charge induction monitoring system is developed to effectively forecast the dynamic disasters caused by coal failure. Specifically, a digital finite impulse response (FIR) filter is designed to denoise and filter the signal, and the time-frequency domain evolution of induced charge signals is analyzed during coal failure experiments. The quantitative relationships between the induced electric charge and stress-strain energy, and ultimately, between induced electric charge and coal deformation/failure, are revealed. Ultimately, the electric charge sensor exhibits high signal collection frequency and high sensitivity, and the FIR low-pass filter constructed in MATLAB effectively denoises and filters induced charge signals. The main frequency range of the white noise is 50–500 Hz, and the main frequency of the charge signal induced by coal deformation and failure is concentrated in the range of 0–50 Hz. The optimal distances for monitoring cubic and cylindrical raw coal samples using this sensor are 9 mm and 11 mm, respectively. Notably, strain energy is released faster when it can dissipate more readily, and induced charge pulses become denser when more intense signals produce large fluctuations. A method is proposed to identify coal deformation and failure based on changes in the induced electric charge. This study provides a new means of monitoring the early warning signs of dynamic coal mine disasters. Based on our experimental results and conclusions, a new method is proposed to identify coal deformation and failure based on changes in the induced electric charge. The precursor to the moment of coal failure can be identified by monitoring the amplitude of the induced charge, the dynamic trend of fluctuation, and the cumulative number of induced electric charge pulses during the process of coal deformation.

Journal of Rock Mechanics and Geotechnical EngineeringVol. 17(7)
Liaoning University (CN), Liaoning Technical University (CN), Inner Mongolia Yili Industrial Group (China) (CN), Northeastern University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Climate action
Openalex Percentile: Top 5%
Earthquake Detection and Analysis
4.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.