Effect of trabeculectomy with mitomycin C versus ologen implant in reducing intraocular pressure: A comparative study in patients with primary open-angle glaucoma

: To compare the efficacy of mitomycin C (MMC) and Ologen implant (OLO) as adjuvants in Trabeculectomy in patients with POAG in eastern India. : It was a hospital based prospective randomized parallel group comparative study from November 2019 to April 2021. Forty eyes of forty patients of POAG with inadequate intraocular pressure (IOP) control were enrolled and randomly divided them into two groups of twenty. Group A (MMC) patients underwent MMC trabeculectomy, while Group B (OLO) patients underwent OLO trabeculectomy. All the cases were followed up post-operatively for six months, and the recorded IOP of each visit was analyses using software R 4.0.3 and R-studio. : The preoperative IOP for the OLO group was 34.0 mmHg (IQR: 30.75 – 38.0), while for the MMC intervention group it was 36.50 mmHg (IQR: 31- 42). The difference in IOP between the two groups was insignificant (p= 0.24). On the first postoperative day, the IOP in the MMC group was 10.05 ± 3.65 mmHg and in the OLO group it was 10.35 ± 2.13 mmHg. Seven days after surgery, the mean IOP in MMC group was 9.45 ± 3.0 mmHg, while it was 11.50 ± 2.52 mmHg in the OLO group. One month after surgery, the mean IOP in the MMC group was 11.15 ± 4.25 mmHg, whereas it was 11.50±5.02 mmHg in OLO group. At 3 months postoperatively, the mean IOP in the MMC group was 12.25± 5.17 mmHg, while it was 12.70± 1.84 mmHg in the OLO group. Six months after surgery, the mean IOP in the MMC group was 10.50± 2.72 mmHg, whereas in the OLO group it was 13.35± 2.94 mmHg. In both the groups, there was significant reduction of IOP (p value < 0.05) observed in all postoperative visits. : In trabeculectomy surgery on POAG eyes, the MMC and OLO implants both successfully lower IOP. Between the two groups, there was no statistically significant difference in the success rate.

Authors

Institutions

Publication Details

Journal
Indian Journal of Clinical and Experimental Ophthalmology
Published
2024-09-15
DOI
https://doi.org/10.18231/j.ijceo.2024.083
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of trabeculectomy with mitomycin C versus ologen implant in reducing intraocular pressure: A comparative study in patients with primary open-angle glaucoma

Naresh Desinayak, Pallavi Shree
Indian Journal of Clinical and Experimental Ophthalmology
Glaucoma and retinal disorders
article

Effect of trabeculectomy with mitomycin C versus ologen implant in reducing intraocular pressure: A comparative study in patients with primary open-angle glaucoma

Naresh Desinayak, Pallavi Shree
article en

Abstract

: To compare the efficacy of mitomycin C (MMC) and Ologen implant (OLO) as adjuvants in Trabeculectomy in patients with POAG in eastern India. : It was a hospital based prospective randomized parallel group comparative study from November 2019 to April 2021. Forty eyes of forty patients of POAG with inadequate intraocular pressure (IOP) control were enrolled and randomly divided them into two groups of twenty. Group A (MMC) patients underwent MMC trabeculectomy, while Group B (OLO) patients underwent OLO trabeculectomy. All the cases were followed up post-operatively for six months, and the recorded IOP of each visit was analyses using software R 4.0.3 and R-studio. : The preoperative IOP for the OLO group was 34.0 mmHg (IQR: 30.75 – 38.0), while for the MMC intervention group it was 36.50 mmHg (IQR: 31- 42). The difference in IOP between the two groups was insignificant (p= 0.24). On the first postoperative day, the IOP in the MMC group was 10.05 ± 3.65 mmHg and in the OLO group it was 10.35 ± 2.13 mmHg. Seven days after surgery, the mean IOP in MMC group was 9.45 ± 3.0 mmHg, while it was 11.50 ± 2.52 mmHg in the OLO group. One month after surgery, the mean IOP in the MMC group was 11.15 ± 4.25 mmHg, whereas it was 11.50±5.02 mmHg in OLO group. At 3 months postoperatively, the mean IOP in the MMC group was 12.25± 5.17 mmHg, while it was 12.70± 1.84 mmHg in the OLO group. Six months after surgery, the mean IOP in the MMC group was 10.50± 2.72 mmHg, whereas in the OLO group it was 13.35± 2.94 mmHg. In both the groups, there was significant reduction of IOP (p value < 0.05) observed in all postoperative visits. : In trabeculectomy surgery on POAG eyes, the MMC and OLO implants both successfully lower IOP. Between the two groups, there was no statistically significant difference in the success rate.

Indian Journal of Clinical and Experimental OphthalmologyVol. 10(3)
Hi-Tech Medical College & Hospital (IN), Central Rice Research Institute (IN)
Openalex Percentile: Top 72%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of trabeculectomy with mitomycin C versus ologen implant in reducing intraocular pressure: A comparative study in patients with primary open-angle glaucoma — Naresh Desinayak, Pallavi Shree · Indian Journal of Clinical and Experimental Ophthalmology (2024) | TGRS Research Map | TGRS