Feasibility of a less invasive supercharged end-to-side anterior interosseous nerve to ulnar motor nerve transfer

The object of this study was to perform an anatomical dissection of Thiel-embalmed specimens in a step-by-step procedure, to establish a 'safe zone' in which to perform a less invasive supercharged end-to-side (SETS) anterior interosseous nerve to ulnar motor nerve transfer without tension and to demonstrate its feasibility. The sample size was calculated with a 5 mm error to reach a 95% confidence interval. Dissection was performed in 15 specimens and the 'safe zone' was established between 40 and 90 mm proximal to the pisiform. Several surgical tips are recommended to help complete the procedure. A reproducible 'safe zone' was found for performing a SETS anterior interosseous to ulnar motor nerve transfer with 95% certainty, reducing soft tissue damage and enhancing the original surgical technique.

Authors

Institutions

Publication Details

Journal
Journal of Hand Surgery (European Volume)
Published
2024-09-28
DOI
https://doi.org/10.1177/17531934241278885
Primary Topic
Nerve Injury and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of a less invasive supercharged end-to-side anterior interosseous nerve to ulnar motor nerve transfer

Javier Cervera-Irimia, Miguel Tovar-Bazaga
1 links
Journal of Hand Surgery (European Volume)
Nerve Injury and Rehabilitation
article

Feasibility of a less invasive supercharged end-to-side anterior interosseous nerve to ulnar motor nerve transfer

Javier Cervera-Irimia, Miguel Tovar-Bazaga
article en

Abstract

The object of this study was to perform an anatomical dissection of Thiel-embalmed specimens in a step-by-step procedure, to establish a 'safe zone' in which to perform a less invasive supercharged end-to-side (SETS) anterior interosseous nerve to ulnar motor nerve transfer without tension and to demonstrate its feasibility. The sample size was calculated with a 5 mm error to reach a 95% confidence interval. Dissection was performed in 15 specimens and the 'safe zone' was established between 40 and 90 mm proximal to the pisiform. Several surgical tips are recommended to help complete the procedure. A reproducible 'safe zone' was found for performing a SETS anterior interosseous to ulnar motor nerve transfer with 95% certainty, reducing soft tissue damage and enhancing the original surgical technique.

Journal of Hand Surgery (European Volume)Vol. 50(4)
Hospital Universitario Fundación Jiménez Díaz (ES)
Openalex Percentile: Top 69%
Nerve Injury and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.