Finite element analysis of distraction osteogenesis with a new extramedullary internal distractor

Distraction osteogenesis (DO) is a bone regenerative maneuver, which is conventionally done with external fixators and, more recently, with telescopic intramedullary nails. Despite the proven effectiveness, external approaches are intrusive to the patient's life while intramedullary nailing damages the growth plates, making them unsuitable for pediatric patients. An internal DO plate fixator (IDOPF) was developed for pediatric patients to address these limitations. The objective of this study was to test the hypothesis that the IDOPF can withstand a partial weight bearing scenario and create a favorable mechanical microenvironment at the osteotomy gap for bone regeneration as the device elongates. A finite element model of a surrogated long bone diaphysis osteotomy fixation by means of the IDOPF was created and subjected to axial compression, bending and torsion. As the osteotomy gap increased from 2 mm to 20 mm, under compression, The average axial interfragmentary strains decreased from 2.33% to 0.35%. Stress increased from 179 MPa to 281 MPa at the contact interfaces of the telescopic compartments, which exceeded the endurance limit of stainless steel (270 MPa) but was below its yield limit (415 MPa). These results demonstrate, that the IDOPF can withstand a partial load bearing scenario and provide a stable biomechanical environment conductive to bone healing. However, high contact stresses at the telescopic interfaces of the device are likely to cause wear, as is frequently reported in telescopic fixators. This study is a step towards refining the IDOPF design for clinical use.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2024-09-28
DOI
https://doi.org/10.1080/10255842.2024.2406367
Citations
3
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
1.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite element analysis of distraction osteogenesis with a new extramedullary internal distractor

Isabelle Villemure, Carl‐Éric Aubin, Marie‐Lyne Nault, Mohammad Ali Bagheri
3 citations
Computer Methods in Biomechanics & Biomedical Engineering
Bone fractures and treatments
1.16
article

Finite element analysis of distraction osteogenesis with a new extramedullary internal distractor

Isabelle Villemure, Carl‐Éric Aubin, Marie‐Lyne Nault, Mohammad Ali Bagheri
article en
3 citations

Abstract

Distraction osteogenesis (DO) is a bone regenerative maneuver, which is conventionally done with external fixators and, more recently, with telescopic intramedullary nails. Despite the proven effectiveness, external approaches are intrusive to the patient's life while intramedullary nailing damages the growth plates, making them unsuitable for pediatric patients. An internal DO plate fixator (IDOPF) was developed for pediatric patients to address these limitations. The objective of this study was to test the hypothesis that the IDOPF can withstand a partial weight bearing scenario and create a favorable mechanical microenvironment at the osteotomy gap for bone regeneration as the device elongates. A finite element model of a surrogated long bone diaphysis osteotomy fixation by means of the IDOPF was created and subjected to axial compression, bending and torsion. As the osteotomy gap increased from 2 mm to 20 mm, under compression, The average axial interfragmentary strains decreased from 2.33% to 0.35%. Stress increased from 179 MPa to 281 MPa at the contact interfaces of the telescopic compartments, which exceeded the endurance limit of stainless steel (270 MPa) but was below its yield limit (415 MPa). These results demonstrate, that the IDOPF can withstand a partial load bearing scenario and provide a stable biomechanical environment conductive to bone healing. However, high contact stresses at the telescopic interfaces of the device are likely to cause wear, as is frequently reported in telescopic fixators. This study is a step towards refining the IDOPF design for clinical use.

Computer Methods in Biomechanics & Biomedical EngineeringVol. 29(3)
Centre Hospitalier Universitaire Sainte-Justine (CA), Polytechnique Montréal (CA), Université de Montréal (CA)
Canada First Research Excellence Fund
Openalex Percentile: Top 20%
Bone fractures and treatments
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.